84 / 92 page ![]() Rev.1.10 Nov 14, 2005 Page 84 of 91 REJ03B0166-0110 3803 Group (Spec.H QzROM version) PRELIMINARY Notice: This is not a final specification. Some parametric limits are subject to change. APPENDIX NOTES ON PROGRAMMING 1. Processor Status Register (1) Initializing of processor status register Flags which affect program execution must be initialized after a reset. In particular, it is essential to initialize the T and D flags because they have an important effect on calculations. <Reason> After a reset, the contents of the processor status register (PS) are undefined except for the I flag which is “1”. Fig 1. Initialization of processor status register (2) How to reference the processor status register To reference the contents of the processor status register (PS), execute the PHP instruction once then read the contents of (S+1). If necessary, execute the PLP instruction to return the PS to its original status. Fig 2. Stack memory contents after PHP instruction execution 2. BRK instruction (1) Interrupt priority level When the BRK instruction is executed with the following conditions satisfied, the interrupt execution is started from the address of interrupt vector which has the highest priority. • Interrupt request bit and interrupt enable bit are set to “1”. • Interrupt disable flag (I) is set to “1” to disable interrupt. 3. Decimal calculations (1) Execution of decimal calculations The ADC and SBC are the only instructions which will yield proper decimal notation, set the decimal mode flag (D) to “1” with the SED instruction. After executing the ADC or SBC instruction, execute another instruction before executing the SEC, CLC, or CLD instruction. (2) Notes on status flag in decimal mode When decimal mode is selected, the values of three of the flags in the status register (the N, V, and Z flags) are invalid after a ADC or SBC instruction is executed. The carry flag (C) is set to “1” if a carry is generated as a result of the calculation, or is cleared to “0” if a borrow is generated. To determine whether a calculation has generated a carry, the C flag must be initialized to “0” before each calculation. To check for a borrow, the C flag must be initialized to “1” before each calculation. Fig 3. Execution of decimal calculations 4. JMP instruction When using the JMP instruction in indirect addressing mode, do not specify the last address on a page as an indirect address. 5. Multiplication and Division Instructions • The index X mode (T) and the decimal mode (D) flags do not affect the MUL and DIV instruction. • The execution of these instructions does not change the contents of the processor status register. 6. Ports The contents of the port direction registers cannot be read. The following cannot be used: • The data transfer instruction (LDA, etc.) • The operation instruction when the index X mode flag (T) is “1” • The instruction with the addressing mode which uses the value of a direction register as an index • The bit-test instruction (BBC or BBS, etc.) to a direction register • The read-modify-write instructions (ROR, CLB, or SEB, etc.) to a direction register. Use instructions such as LDM and STA, etc., to set the port direction registers. 7. Instruction Execution Timing The instruction execution time can be obtained by multiplying the frequency of the internal clock φ by the number of cycles mentioned in the 740 Family Software Manual. The frequency of the internal clock φ is the twice the XIN cycle in high-speed mode, 8 times the XIN cycle in middle-speed mode, and the twice the XCIN in low-speed mode. 8. Reserved Area, Reserved Bit Do not write any data to the reserved area in the SFR area and the special page. (Do not change the contents after reset.) 9. CPU Mode Register Be sure to fix bit 3 of the CPU mode register (address 003B16) to “1”. Reset Initializing of flags Main program Stored PS (S) (S) + 1 Set D flag to “1” ADC or SBC instruction NOP instruction SEC, CLC, or CLD instruction |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |