| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
LAN8808D Datasheet(PDF) 51 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
LAN8808D Datasheet(HTML) 51 Page - Microchip Technology |
|
51 / 80 page ![]() LAN8808D © 2026 Microchip Technology Inc. and its subsidiaries DS00005833C-page 51 5.18 Power Management The device incorporates a number of power-management modes and features that provide methods to consume less energy. These are discussed in the following sections. 5.18.1 SMART POWER SAVING For shorter cable lengths (< ~70 meters) the SNR is sufficiently high to allow the reduction of ADC resolution as well as DSP taps. Based on the detected cable length, the device automatically reduces power consumption by approximately 20 mW. 5.18.2 ENERGY-DETECT POWER-DOWN MODE The device supports an Energy-Detect Power-Down (EDPD) mode to save power when there is no link partner sending signals. In EDPD mode, the device shuts down all transceiver blocks, except for the transmitter and energy detect circuits. Power can be reduced further by extending the time interval between the transmissions of link pulses to check for the presence of a link partner. The periodic transmission of link pulses is needed to ensure the device and its link partner, when operating in the same low-power state and with Auto-MDI/MDI-X disabled, can wake up when the cable is con- nected between them. By default, EDPD mode is disabled after power-up. EDPD is enabled by setting the p_edpd_en bit in the EDPD Control register within the MMD address space. EDPD operation may be adjusted via the p_edpd_mask_timer[1:0], p_edpd_timer[1:0], and p_EDPD_random_dis fields in the EDPD Control register within the MMD address space. The energy detection change status can be read from the Interrupt Status register. The current energy detection status can be read from the EDPD low power bit in the Analog Control Register 8. While the p_edpd_en bit is set, the cable link status will be down, and the energy detection normally monitors pairs A and B for energy. If the link speed is forced to 1000 Mbps (by disabling auto-negotiation and setting the speed manually), the energy detection monitors all four pairs. For cable diagnostic purposes, individual wire pairs may be monitored by forcing the link speed to 1000 Mbps and selecting the wire pair using the EDPD Wire Pair Selection bits in the Analog Control Register 8. Enhanced Mode 11 N/A Reserved Enhanced Mode 12 (Parallel Detect Fault) Inactive No parallel detect fault Active Parallel detect fault Blinking N/A Enhanced Mode 13 N/A Reserved Enhanced Mode 14 (Force LED Off) Inactive LED off Active N/A Blinking N/A Enhanced Mode 15 (Force LED On) Inactive N/A Active LED on Blinking N/A TABLE 5-10: EXTENDED MODE OPERATION (CONTINUED) Mode PORTxLEDy Definition |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |