| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
M29DW128F60NF1F Datasheet(PDF) 18 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M29DW128F60NF1F Datasheet(HTML) 18 Page - STMicroelectronics |
|
18 / 93 page ![]() 3 Bus operations M29DW128F 18/93 3.5 Automatic Standby If CMOS levels (VCC ± 0.2V) are used to drive the bus and the bus is inactive for 300ns or more the memory enters Automatic Standby where the internal Supply Current is reduced to the Standby Supply Current, ICC2. The Data Inputs/Outputs will still output data if a Bus Read operation is in progress. 3.6 Special Bus Operations Additional bus operations can be performed to read the Electronic Signature, verify the Protection Status of the Extended Memory Block (second section), and apply and remove Block Protection. These bus operations are intended for use by programming equipment and are not usually used in applications. They require VID to be applied to some pins. 3.6.1 Read Electronic Signature The memory has two codes, the Manufacturer code and the Device code used to identify the memory. These codes can accessed by performing read operations with control signals and addresses set as shown in Table 4 and Table 6. These codes can also be accessed by issuing an Auto Select command (see Auto Select command in Section 6: Command Interface). 3.6.2 Verify Extended Block Protection Indicator The Extended Block is divided in two sections of which one is Factory Locked and the second one is either Customer Lockable or Customer Locked. The Protection Status of the second section of the Extended Block (Customer Lockable or Customer Locked) can be accessed by reading the Extended Block Protection Indicator. This is performed by applying the signals as shown in Table 5 and Table 8. The Protection Status of the Extended Block is then output on bits DQ7 and DQ6 of the Data Input/Outputs. (see Table 3 and Table 6, Bus Operations). The Protection Status of the Extended Block can also be accessed by issuing an Auto Select command (see Auto Select command in Section 6: Command Interface). 3.6.3 Verify Block Protection Status The Protection Status of a Block can be directly accessed by performing a read operation with control signals and addresses set as shown in Table 5 and Table 8. If the Block is protected, then 01h (in x8 mode) is output on Data Input/Outputs DQ0-DQ7, otherwise 00h is output. 3.6.4 Hardware Block Protect The VPP/WP pin can be used to protect the four outermost parameter blocks. When VPP/WP is at VIL the four outermost parameter blocks are protected and remain protected regardless of the Block Protection Status or the Reset/Block Temporary Unprotect pin state. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |