| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
320 Datasheet(PDF) 63 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
320 Datasheet(HTML) 63 Page - Intel Corporation |
|
63 / 82 page ![]() Datasheet 63 Thermal Specifications and Design Considerations 5 Thermal Specifications and Design Considerations 5.1 Processor Thermal Specifications The Celeron D processor requires a thermal solution to maintain temperatures within operating limits as set forth in Section 5.1.1. Any attempt to operate the processor outside these operating limits may result in permanent damage to the processor and potentially other components within the system. As processor technology changes, thermal management becomes increasingly crucial when building computer systems. Maintaining the proper thermal environment is key to reliable, long-term system operation. A complete thermal solution includes both component and system level thermal management features. Component level thermal solutions can include active or passive heatsinks attached to the processor Integrated Heat Spreader (IHS). Typical system level thermal solutions may consist of system fans combined with ducting and venting. For more information on designing a component level thermal solution, refer to the applicable thermal design guide. Note: The boxed processor will ship with a component thermal solution. Refer to Chapter 7 for details on the boxed processor. 5.1.1 Thermal Specifications To allow for the optimal operation and long-term reliability of Intel processor-based systems, the system/processor thermal solution should be designed such that the processor remains within the minimum and maximum case temperature (TC) specifications when operating at or below the Thermal Design Power (TDP) value listed per frequency in Table 5-1. Thermal solutions not designed to provide this level of thermal capability may affect the long-term reliability of the processor and system. For more details on thermal solution design, refer to the appropriate processor thermal design guidelines. The Celeron D processor introduces a new methodology for managing processor temperatures through fan speed control. Selection of the appropriate fan speed will be based on the temperature reported by the processor’s Thermal Diode. The fan must be turned on to full speed when TDIODE is at or above TCONTROL and TC must be maintained at or below TC (max) as defined by the processor thermal specifications in Table 5-1. The fan speed may be lowered when the processor temperature can be maintained below TCONTROL as measured by the thermal diode. Systems implementing fan speed control must be designed to read temperature values from the diode and TCONTROL register and take appropriate action. Systems that do not alter the fan speed (always at full speed) only need to guarantee the case temperature meets specifications in Table 5-1. The case temperature is defined at the geometric top center of the processor IHS. Analysis indicates that real applications are unlikely to cause the processor to consume maximum power dissipation for sustained periods of time. Intel recommends that complete thermal solution designs target the Thermal Design Power (TDP) indicated in Table 5-1 instead of the maximum processor |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |