5 / 41 page ![]() Data Sheet ADIS16505 Rev. C | Page 5 of 41 Parameter Test Conditions/Comments Min Typ Max Unit LOGIC INPUTS5 Input Voltage High, VIH 2.0 V Low, VIL 0.8 V RST Pulse Width 1 μs Input Current Logic 1, IIH VIH = 3.3 V 10 μA Logic 0, IIL VIL = 0 V All Pins Except RST 10 μA RST Pin 0.33 mA Input Capacitance, CIN 10 pF DIGITAL OUTPUTS Output Voltage High, VOH Source current (ISOURCE) = 0.5 mA 2.4 V Low, VOL Sink current (ISINK) = 2.0 mA 0.4 V FLASH MEMORY Endurance6 10,000 Cycles Data Retention7 TJ = 85°C 20 Years FUNCTIONAL TIMES8 Time until data is available Power-On Start-Up Time 310 ms Reset Recovery Time9 GLOB_CMD, Bit 7 = 1 (see Table 112) 255 ms Factory Calibration Restore GLOB_CMD, Bit 1 = 1 (see Table 112) 136 ms Flash Memory Backup GLOB_CMD, Bit 3 = 1 (see Table 112) 70 ms Flash Memory Test Time GLOB_CMD, Bit 4 = 1 (see Table 112) 30 ms Self Test Time10 GLOB_CMD, Bit 2 = 1 (see Table 112) 24 ms CONVERSION RATE 2000 SPS Initial Clock Accuracy 3 % Sync Input Clock 1.9 2.1 kHz POWER SUPPLY, VDD Operating voltage range 3.0 3.6 V Power Supply Current11 Normal mode, VDD = 3.3 V 44 55 mA 1 Cross-axis sensitivity is the sine of this number. 2 This measurement is based on the deviation from a best fit linear model. 3 Bias repeatability provides an estimate for long-term drift in the bias, as observed during 500 hours of high temperature operating life (HTOL) at 105°C. 4 All specifications associated with the accelerometers relate to the full-scale range of ±8 g, unless otherwise noted. 5 The digital input/output signals use a 3.3 V system. 6 Endurance is qualified as per JEDEC Standard 22, Method A117, measured at −40°C, +25°C, +85°C, and +125°C. 7 The data retention specification assumes a junction temperature (TJ) of 85°C per JEDEC Standard 22, Method A117. Data retention lifetime decreases with TJ. 8 These times do not include thermal settling and internal filter response times, which may affect overall accuracy. 9 The RST line must be in a low state for at least 10 μs to ensure a proper reset initiation and recovery. 10 The self test time can extend when using external clock rates lower than 2000 Hz. 11 Power supply current transients can reach 100 mA during initial startup or reset recovery. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |