| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
ZSSC3123AI2R Datasheet(PDF) 18 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
ZSSC3123AI2R Datasheet(HTML) 18 Page - Renesas Technology Corp |
|
18 / 62 page ![]() ZSSC3123 Datasheet Nov 19, 2021 Page 18 © 2021 Renesas Electronics Symbol Description RES Programmable CDC resolution of 8, 10, 12, or 14 bits (bit setting in Table 30) CMULT Capacitance range multiplier (see Table 5) CDC_Offset CDC offset trim setting (see section 9.2.1.4 and Table 30) 9.2.1.3 Differential A differential capacitive sensor includes two capacitors C0 and C1 that are captured as a ratio. The differential sensor is built so that the sensor input capacitance C0 increases while the external reference capacitance C1 decreases over the input signal range, but the total sum always remains constant. Equation 8 and Equation 9 describe the CDC output for a differential sensor capacitance measurement. The CDC_Reference and CDC_Offset capacitor trim bits must be set to zero, and the Differential bit must be set to one. (See Table 30 for bit numbers and settings). The Mult bits should be set so that the total capacitance (C0 + C1) falls in the corresponding capacitance range (see Table 5). The sum of C0 and C1 must not be larger than the selected Mult’s maximum input range, except when CC is used as a decoupling capacitor. In differential mode special sensor types can allow a non-galvanic connection with an external isolating capacitor CCC between the sensor and the CC pin to avoid wear caused by mechanical moving parts. SENSOR C Z CC 0 01 Equation 8 RES CDC SENSOR ZZ 2 Equation 9 Where: Symbol Description ZSENSOR Measured sensor ratio; must be in the range [0 to 1] C0 Input sensor capacitance (moves in the opposite direction of C1) C1 External reference capacitance (moves in the opposite direction of C0) ZCDC Digital raw converted capacitance value RES Programmable CDC resolution of 8, 10, 12, or 14 bits (bit setting in Table 30) 9.2.1.4 Capacitive Range Selection Whether the application uses a single-ended or a differential sensor, the correct capacitance range as defined in Table 5 must be selected using the Mult bits, which are configured in the C_Config register (see Table 30). If using a single-ended sensor, then the minimum and maximum capacitance inputs should fall into the specified ranges. If using a differential sensor then the total capacitance (C0 + C1) must fall into this range. The Mult range affects the conversion time (see section 10.2). Note: If the externally applied capacitance exceeds the configured capacitance range, the converted output signal can still show an apparently correct value, which is not valid. The limit is about 500% of the selected maximum input value. For example, for a capacitance setting of Mult1, CDC_Offset at zero, and CDC_Reference at 7, an input value above 117pF will give a non-saturated input value. Table 5. CDC Multiplier EEPROM Encoding (CDC_Mult) Frequency Multiplier (Mult) Reference Multiplier Total Capacitance Multiplier (CMULT) Capacitance Range (Full Scale Values) 00BIN 1 1.44 1.44 2pF to 8pF 01BIN 2 2.88 5.76 8pF to 32pF 10BIN 4 5.76 23.04 32pF to 130pF 11BIN 8 11.52 92.16 130pF to 260pF |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |