| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
IPC01 Datasheet(PDF) 2 Page - Micropac Industries |
|
|
|||||||||||||||||||||||||||||
IPC01 Datasheet(HTML) 2 Page - Micropac Industries |
|
2 / 9 page ![]() BY MICROPAC TM Industrial Power Controller Micropac Industries cannot assume any responsibility for any circuits shown, or represent that they are free from patent infringement. Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible. Micropac Industries, Inc. 905 E. Walnut St., Garland, TX 75040 (972) 272-3571 Fax (972) 494-2281 ©March 2013 www.micropac.com E-MAIL: microsales@micropac.com 12/18/2013 Rev G Pg. 2 of 9 ABSOLUTE MAXIMUM RATINGS 1. External snubbing may be required for Power Controller protection. 2. Reversing output polarity on DC units may cause permanent damage. 3. The I 2t circuit breaker function terminates AC overloads and fault currents per Figures 1 or 2 and DC overloads and fault currents per Figures 3 or 4. AC ELECTRICAL OUTPUT CHARACTERISTICS: TC = -40 to 80° C Description 1 Units Device 40VAC / 10A 280VAC / 5A Rated Operating Voltage VRMS 0 – 40 0 - 280 Overvoltage (Maximum) VRMS 45 310 Transients (Maximum) VPEAK 64 424 Operating Frequency Hz 50 – 450 50 - 450 Current Rating ARMS 10 5 Interrupt Current Rating 2,3 APEAK 100 50 Turn-On / Turn-Off Time 4 mSec 8 8 Turn-On / Turn-Off Delay 6 mSec 12 12 Trip Shutdown Time 3,5 µSec 35 35 Maximum Off-State Leakage @ Rated Voltage µA 500 500 Maximum On-State Voltage Drop @ Rated Current VRMS 0.75 0.75 Maximum On-State Resistance @ Rated Current Ohms 0.15 0.30 1. This is not a “zero crossing Turn-On” IPC. Turn-On at other than zero-crossing will experience a “soft-start” voltage and current equal to the typical Turn-On Rise Time of 8msec. At 60 Hz this is ½ sin of the normal voltage rise and is 2.5 cycles for 400 Hz. 2. Steady state trip current is between 120% and 160% of rated current. See Figures 1 and 2. 3. I 2t trip current is time dependent. See Figures 1 and 2. 4. Output of 10 to 90% / 90 to 10%. 5. Output current measured from fault onset to 10% rated load. 6. “ON” command period is 1 sec minimum with a duty cycle of 10%. Description DC IPC AC IPC Isolation Voltage 1,500 VDC 1,500VDC Load Voltage 75 / 400V VDC 1,2 40 / 280VAC RMS Load Current Less Than 8 Times Rated Operating Current / Self Protecting 3 Self Protecting to MIL-STD-1760E 3 Bias supply voltage, VDD -0.6 to 32 VDC -0.6 to 32 VDC Control Voltage 1 Volt above VDD / 1 Volt below Return 1 Volt above VDD / 1 Volt below Return Operating Temperature, Case -40ºC to +80ºC -40ºC to +80ºC Storage Temperature -55ºC to +85ºC -55ºC to +85ºC |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |