| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
IPC01 Datasheet(PDF) 4 Page - Micropac Industries |
|
|
|||||||||||||||||||||||||||||
IPC01 Datasheet(HTML) 4 Page - Micropac Industries |
|
4 / 9 page ![]() BY MICROPAC TM Industrial Power Controller Micropac Industries cannot assume any responsibility for any circuits shown, or represent that they are free from patent infringement. Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible. Micropac Industries, Inc. 905 E. Walnut St., Garland, TX 75040 (972) 272-3571 Fax (972) 494-2281 ©March 2013 www.micropac.com E-MAIL: microsales@micropac.com 12/18/2013 Rev G Pg. 4 of 9 AC AND DC CHARACTERISTICS: TC = -40 to 80° C Description Units AC and DC Devices Maximum Bias supply, VDD VDC 32 Maximum Bias current mA 35 Maximum Control voltage range 1 (CMOS Configuration) VDC -0.5 to ≤ VDD Minimum Turn-on voltage (VIH) 2 VDC 3.9 Maximum Turn-off voltage (VIL) 2 VDC 2.0 Trip Reset Time 3 Seconds 100 Status Supply Voltage (open Collector) VDC 32 Status off leakage current µADC 4 Status on voltage VDC 0.4 Junction temperature ºC 150 Thermal resistance, JC ºC/W 5 Output Capacitance pF 3,000 Input to Output Capacitance pF 25 1. Input transitions should be “bounce-less contact” with transitions of <1 msec. 2. TTL Logic may require a pull-up resistor to ensure a “high” input condition. 3. The IPC has load current memory. A period of 100 seconds between an overload, or shorted load restart allows for full current startup. Table 1: Short circuit and Status Sequence Shorted at Turn On Shorted while On Input Control 0 1 1 0 1 1 1 1 0 1 Load Current 0 0 0 0 1 1 0 0 0 1 Switch Status 0 0 0 0 1 1 0 0 0 1 Output Short Applied Short Applied Short Removed Load Load Load Short Applied Short Removed Load Load Notes: 1. Unit Powers up in the OFF condition with application of VDD . However, it is highly recommended that Control be held low (Off) during the initiation of Power to ensure there is no transient reset / start signaling. 2. Fault Status reports only when VDD is present. 3. An OFF Control to ON Control transition is required to first turn the Unit On. 4. A loss of VDD will return the output state to OFF. 5. Truth Table Power sequencing: Output Status open collector pull-up resistor is assigned a separate and always on voltage producing a “1” when “Open”. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |