35 / 53 page ![]() PM6670 Device description 35/53 7.1.11 Over Voltage and Under Voltage Protections When the switching output voltage is about 115% of its nominal value, a latched Over- Voltage Protection (OVP) occurs. In this case the synchronous rectifier immediately turns on while the high-side MOSFET turns OFF. The output capacitor is rapidly discharged and the load is preserved from being damaged. The OVP is also active during the soft start. Once an OVP has occured, a toggle on S5 pin or a Power-On-Reset is necessary to exit from the latched state. When the switching output voltage is below 70% of its nominal value, a latched Under- Voltage Protection occurs. This event causes the switching section to be immediately disabled and both switches to be opened. The controller enters in Soft-End mode and the output is eventually kept to ground, turning the low side MOSFET on when the voltage is lower than 400mV. If S3 and S5 are forced low, the low-side MOSFET is released and only the 22 Ω switch is active. The Under-Voltage Protection circuit is enabled only at the end of the soft-start. Once an UVP has toccured, a toggle on S5 pin or a Power-On-Reset is necessary to clear the fault state and restart the device. 7.1.12 Device thermal protection The internal control circuitry of the PM6670 self-monitors the junction temperature and turns all outputs off when the 150°C limit has been overrun. This event causes the switching section to be immediately disabled and both switches to be opened. The controller enters in Soft-End Mode and the output is eventually kept to ground, turning the low side MOSFET on when the voltage is lower than 400mV. If S3 and S5 are forced low, the low-side switch is released and only the 22 Ω discharge MOSFET is active. The thermal fault is a latched protection and normal operating condition is restored by a Power-On Reset or toggling S5. Table 10. OV, UV and OT faults management Fault Conditions Action VDDQ over voltage VDDQ > 115% of the nominal value LGATE pin is forced high and the device latches off. Exit by a Power-On Reset or toggling S5 VDDQ under voltage VDDQ < 70% of the nominal value LGATE pin is forced high after the Soft-End, then the device latches off. Exit by a Power-On Reset or toggling S5. Junction over temperature TJ > +150°C LGATE pin is forced high after the Soft-End, then the device latches off. Exit by a Power-On Reset or toggling S5 after 15°C temperature drop. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |