| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
TDA7546 Datasheet(PDF) 65 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
TDA7546 Datasheet(HTML) 65 Page - STMicroelectronics |
|
65 / 68 page ![]() TDA7546 Application notes 65/68 8 Application notes 8.1 Typical RDS data transfer: 1. After power up the device, the PLL must be initialized and enabled to generate the 8.55 MHz or 8.664 MHz system clock (fsys). If the XTI frequency is already 8.55 MHz or 8.664 MHz, this point can be skipped. If not, the pllreg4-0 register must be programmed via I2C/SPI. If the XTI frequency is smaller then 8.55 MHz, the reduced maximum I2C/SPI speed must be considered. After the pllreg4-0 register has been programmed, 500 us and additional 25 XTI input clock cycles must be waited until the PLL is locked and the system clock fsys is switched over to the PLL output clock. Then the next I2C/SPI transfer is allowed with its maximum speed specified for the 8.55/8.664 MHz system clock (fsys). 2. In the next I2C/SPI transfer the interrupt source will be set to “buffer not empty” (itsrc[2:0] = 001) and a resynchronization should be forced (rds_int[5] = 1), to be sure that the buffer is empty and not filled with spurious RDS data. To do this only an write access to the first register rds_int is needed. 3. Now the pin INTN must be continuously checked for an interrupt (active low). If there is an interrupt the five registers rds_int, rds_qu, rds_corrp, rds_bd_h and rds_bd_l must be read out to get the RDS data. The next interrupt can not be expected before 22 ms. 4. If it is not possible to service the interrupt in time, then the RDS buffer can store up to 24 RDS bocks. If the buffer is full and the data could not be read before the next RDS block, the “buffer overflow” flag (rds_corrp[0] = 1) will be set. In this case at least one RDS block is missed. The “buffer overflow” flag is only cleared, if the whole RDS buffer is read out. If there is no pin available for checking the INTN pin, then it is possible to read out the RDS data by I2C/SPI polling. Only the “buffer not empty” flag (rds_int[6]) can be used for that. If rds_int[6] bit is set, the I2C/SPI transfer must be continued, until at least the four register rds_qu, rds_corrp, rds_bd_h and rds_bd_l are read out. This must be done until rds_int[6] bit is set to zero (last RDS block). It is possible that the last RDS block is the same as the last but one RDS block. This is the case if just one RDS block was stored in the RAM buffer. If they are identical, one of them can be skipped. If another interrupt source is used instead of “buffer not empty” for the INTN pin, also the polling mode must be used for reading out the whole RDS buffer, as described above. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |