Motor de Búsqueda de Datasheet de Componentes Electrónicos
  Spanish  ▼
ALLDATASHEET.ES

X  

RACM100-S Datasheet(PDF) 2 Page - Recom International Power

No. de pieza RACM100-S
Descripción Electrónicos  100 Watt Enclosed Case Style Single Output
PDF  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrónico  RECOM [Recom International Power]
Página de inicio  http://www.recom-international.com
Logo RECOM - Recom International Power

RACM100-S Datasheet(HTML) 2 Page - Recom International Power

  RACM100-S Datasheet HTML 1Page - Recom International Power RACM100-S Datasheet HTML 2Page - Recom International Power RACM100-S Datasheet HTML 3Page - Recom International Power RACM100-S Datasheet HTML 4Page - Recom International Power RACM100-S Datasheet HTML 5Page - Recom International Power  
Zoom Inzoom in Zoom Outzoom out
 2 / 5 page
background image
20
10
40
30
70
60
50
80 90 100
Load (%)
86
84
88
90
92
94
115VAC
230VAC
85
20
40
60
80
100
125
100
115
130
145
160
175
264
Input Voltage (V)
50% Load
100% Load
85
84
86
88
90
92
94
130 150
190 230
250
110
90
170
240
264
Input Voltage (V)
40
30
60
50
80
70
90
100
Load (%)
0
1
115VAC
230VAC
AC/DC Converter
MED-2
REV.: 3/2015
www.recom-power.com
Specifications (measured at TA= 25°C, 250VAC, full load and after warm-up)
PROTECTIONS
Parameter
Condition
Value
Input Fuse
internal line and neutral
T3.15A / 250VAC, slow blow type
Short Circuit Protection (SCP)
continuous, auto-recovery
Over Load Protection (OLP)
% of Iout rated
Hiccup Mode, 115% min. / 150% max.
Over Voltage Protection (OVP)
% of Vout nominal
Latch Mode, 115% min. / 135% max.
Isolation Voltage
I/P to O/P
I/P to Chassis
O/P to Chassis
working voltage
4kVAC / 1 minute
1.5kVAC / 1 minute
1.5kVAC / 1 minute
250VAC / continuous
Means of Protection
2MOPP
Leakage Current
264VAC
75µA max.
Medical Device Classification
Type BF applied device
continued on next page
REGULATIONS
Parameter
Condition
Value
Output Voltage Accuracy
230VAC, full load
±1%
Line Voltage Regulation
low line to high line, full load
±0.2%
Load Voltage Regulation
0% to 100% load
10% to 100% load
±0.5% max.
±0.4% max.
Output Voltage Trim
±10%
Transient Peak Deviation
load step from 50% - 75% change at 2.5A/µs
3% Vout max.
Transient Recovery Time
load step from 50% - 75% change at 2.5A/µs
500µs typ.
Efficiency vs. Load
Efficiency vs. Input Voltage
Load vs. Input Voltage
Power Factor vs. Load
RACM100
Series



Html Pages

1 2 3 4 5


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com