| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
ADS8401 Datasheet(PDF) 21 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
ADS8401 Datasheet(HTML) 21 Page - Texas Instruments |
|
21 / 29 page ![]() www.ti.com RESET POWER-ON INITIALIZATION LAYOUT ADS8406 SLAS426A – AUGUST 2004 – REVISED DECEMBER 2004 RESET is an asynchronous active low input signal (that works independently of CS). Minimum RESET low time is 25 ns. Current conversion will be aborted no later than 50 ns after the converter is in the reset mode. In addition, all output latches are cleared (set to zero's) after RESET. The converter goes back to normal operation mode no later than 20 ns after RESET input is brought high. The converter starts the first sampling period 20 ns after the rising edge of RESET. Any sampling period except for the one immediately after a RESET is started with the falling edge of the previous BUSY signal or the falling edge of CS, whichever is later. Another way to reset the device is through the use of the combination of CS and CONVST. This is useful when the dedicated RESET pin is tied to the system reset but there is a need to abort only the conversion in a specific converter. Since the BUSY signal is held high during the conversion, either one of these conditions triggers an internal self-clear reset to the converter just the same as a reset via the dedicated RESET pin. The reset does not have to be cleared as for the dedicated RESET pin. A reset can be started with either of the two following steps. • Issue a CONVST when CS is low and a conversion is in progress. The falling edge of CONVST must satisfy the timing as specified by the timing parameter tsu(AB) mentioned in the timing characteristics table to ensure a reset. The falling edge of CONVST starts a reset. Timing is the same as a reset using the dedicated RESET pin except the instance of the falling edge is replaced by the falling edge of CONVST. • Issue a CS while a conversion is in progress. The falling edge of CS must satisfy the timing as specified by the timing parameter tsu(AB) mentioned in the timing characteristics table to ensure a reset.The falling edge of CS causes a reset. Timing is the same as a reset using the dedicated RESET pin except the instance of the falling edge is replaced by the falling edge of CS. RESET is not required after power on. An internal power-on-reset circuit generates the reset. To ensure that all of the registers are cleared, the three conversion cycles must be given to the converter after power on. For optimum performance, care should be taken with the physical layout of the ADS8406 circuitry. As the ADS8406 offers single-supply operation, it is often used in close proximity with digital logic, microcontrollers, microprocessors, and digital signal processors. The more digital logic present in the design and the higher the switching speed, the more difficult it is to achieve good performance from the converter. The basic SAR architecture is sensitive to glitches or sudden changes on the power supply, reference, ground connections and digital inputs that occur just prior to latching the output of the analog comparator. Thus, driving any single conversion for an n-bit SAR converter, there are at least n windows in which large external transient voltages can affect the conversion result. Such glitches might originate from switching power supplies, nearby digital logic, or high power devices. The degree of error in the digital output depends on the reference voltage, layout, and the exact timing of the external event. On average, the ADS8406 draws very little current from an external reference, as the reference voltage is internally buffered. If the reference voltage is external and originates from an op amp, make sure that it can drive the bypass capacitor or capacitors without oscillation. A 0.1-µF bypass capacitor and a 1-µF storage capacitor are recommended from pin 1 (REFIN) directly to pin 48 (REFM). REFM and AGND should be shorted on the same ground plane under the device. The AGND and BDGND pins should be connected to a clean ground point. In all cases, this should be the analog ground. Avoid connections which are close to the grounding point of a microcontroller or digital signal processor. If required, run a ground trace directly from the converter to the power supply entry point. The ideal layout consists of an analog ground plane dedicated to the converter and associated analog circuitry. 21 |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |