| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
PDBFS220 Datasheet(PDF) 22 Page - Cooper Bussmann, Inc. |
|
|
|||||||||||||||||||||||||||||
PDBFS220 Datasheet(HTML) 22 Page - Cooper Bussmann, Inc. |
|
22 / 23 page ![]() For more information on this see section Conductor & Terminations – Application Considerations in the Cooper Bussmann publication SPD – Selecting Protective Devices on www.cooperbussmann.com UL 508A Industrial Control Panels Conductors for Internal Wiring: Copper conductors only. Conductors are sized based on either the 60°C or 75°C allowable conductor ampacities from UL508A, Table 28.1 (following). The 75°C ampacities can only be used if the termination temperature ratings at both ends of the conductor are rated 75°C or 60°C/75°C. In addition, the conductor insulation is required to be 90°C or higher temperature rated even though the ampacity is based on 60°C or 75°C (UL508A, 29.2.1 & 29.6.1(b)). HVAC Equipment (UL1995): The electrical panel is required to be marked with the assembly SCCR per NEC® 440.4(B). The larger spacing that is mandated in UL508A is not present in UL1995. If the control panel for the HVAC equipment is a listed UL508A panel, then the larger UL508A spacing is required. Power Distribution Block Application UL 1995 Example PDB in 480V UL 1995 HVAC Equipment must have spacing of 3/8˝ through air and 1/2˝ over surface. PDBs listed to UL 1953 meet this spacing as well as most terminal blocks recognized to UL 1059. UL508A, Table 28.1 (Partial) Wire size 60ºC (140ºF) 75ºC (167ºF) AWG (mm 2) Copper Copper 14 (2.1) 15 15 12 (3.3) 20 20 10 (5.3) 30 30 8 (8.4) 40 50 6 (13.3) 55 65 4 (21.2) 70 85 3 (26.7) 85 100 2 (33.6) 95 115 1 (42.4) 110 130 1/0 (53.5) – 150 2/0 (67.4) – 175 3/0 (85.0) – 200 4/0 (107.2) – 230 250 kcmil (127) – 255 300 (152) – 285 350 (177) – 310 400 (203) – 335 500 (253) – 380 600 (304) – 420 700 (355) – 460 750 (380) – 475 800 (405) – 490 900 (456) – 520 1000 (506) – 545 1250 (633) – 590 1500 (760) – 625 1750 (887) – 650 2000 (1013) – 665 NOTES 1 For multiple-conductors of the same size (1/0 AWG or larger) at a terminal, the ampacity is equal to the value in this table for that conductor multiplied by the number of conductors that the terminal is able to accommodate. 1011 SB-BU09622 Page 22 of 23 Data Sheet 1049 Application Notes |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |