5 / 16 page ![]() LA74308LP No.A0898-5/16 POWER ON RESET Condition (SERIAL communication) The POWER ON RESET state covers a period up to the rise of the second C.S. input after fall of POWER ON PULSE generated inside IC when the power is supplied and the STANDBY control is canceled. is the dummy communication. Actually, because of delay of several hundreds ns in the IC, the first DATA condition begins in and the normal SERIAL communication condition begins after . HIGH period for about 2ms Delay of several hundreds ns SERIAL communication condition (First DATA hold) (First C.S.) Dummy communication Power Supply H L STANDBY control (Pin 3) HIGH to cancel STANDBY H L POWER ON PULSE (Signal inside IC) H L C.S. (Pin 6) H L H L POWER ON RESET (IC inside) POWER ON RESET (default) state Data (Pin 8) H L Clock (Pin 7) H L Dummy Data First Data (Second C.S.) First DATA communication |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|