| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
MAXQ3180-RAN+ Datasheet(PDF) 16 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAXQ3180-RAN+ Datasheet(HTML) 16 Page - Maxim Integrated Products |
|
16 / 101 page ![]() Low-Power, Multifunction, Polyphase AFE 16 ______________________________________________________________________________________ Entry into Stop Mode only occurs at the request of the master. To place the MAXQ3180 into Stop Mode, the master must read the ENTER STOP (0xC02) register. Once this register has been read, the MAXQ3180 enters Stop Mode immediately, before the transmission of the final ACK byte by the MAXQ3180. There are three possible ways to bring the MAXQ3180 back out of Stop Mode. • Power Cycle. The MAXQ3180 automatically exits Stop Mode if a power-on reset occurs. Following exit from Stop Mode, all registers are cleared back to their default states, and the MAXQ3180 transitions to Initialization Mode. • External Reset. The MAXQ3180 exits Stop Mode if an external reset is triggered by driving RESET low. Once the RESET pin is released and allowed to return to a high state, the MAXQ3180 comes out of reset and goes into Initialization Mode. All registers are cleared to their default states when exiting Stop Mode in this manner. • External Interrupt. Driving the SSEL pin low causes the MAXQ3180 to exit Stop Mode without undergoing a reset cycle. When exiting Stop Mode in this man- ner, all register and configuration settings are retained, and the MAXQ3180 automatically resumes electric-metering functions and sample processing. Note that when the master is communicating with the MAXQ3180, the SSEL line is normally driven low at the beginning of each SPI command. This means that if the master sends an SPI command after the MAXQ3180 enters Stop Mode, the MAXQ3180 automatically exits Stop Mode. Reset Sources There are several different sources that can cause the MAXQ3180 to undergo a reset cycle. For any type of hardware reset, the RESET pin is driven low when a reset occurs. External Reset This hardware reset is initiated by an external source (such as the master controller or a manual pushbutton press) driving the RESET pin on the MAXQ3180 low. The RESET line must be held low for at least four cycles of the currently selected clock for the external reset to take effect. Once the external reset takes effect, it remains in effect indefinitely as long as RESET is held low. Once the external reset has been released, the MAXQ3180 clears all registers to their default states and resumes execution in Initialization Mode. When an external reset occurs outside of Stop Mode, execution (in Initialization Mode) resumes after four cycles of the currently selected clock (external high-fre- quency crystal for Run Mode, 1MHz internal RC oscilla- tor for LOWPM Mode). As the MAXQ3180 enters Initialization Mode, the LOWPM bit is always cleared CLOCK RESET RESET SAMPLING INTERNAL RESET BEGIN RUNNING IN INITIALIZATION MODE Figure 1. External Reset |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |