4 / 12 page ![]() 4 LTC1860L/LTC1861L 18601Lf SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS tCONV Conversion Time (See Figure 1) q 3.7 4.66 µs fSMPL(MAX) Maximum Sampling Frequency q 150 kHz tdDO Delay Time, SCK ↓ to SDO Data Valid CLOAD = 20pF 45 55 ns q 60 ns tdis Delay Time, CONV ↑ to SDO Hi-Z q 55 120 ns ten Delay Time, CONV ↓to SDO Enabled CLOAD = 20pF q 35 120 ns thDO Time Output Data Remains CLOAD = 20pF q 515 ns Valid After SCK ↓ tr SDO Rise Time CLOAD = 20pF 25 ns tf SDO Fall Time CLOAD = 20pF 12 ns The q denotes specifications which apply over the full operating temperature range, otherwise specifications are TA = 25°C. VCC = 2.7V, VREF = 2.5V, fSCK = fSCK(MAX) as defined in Recommended Operating Conditions, unless otherwise noted. TI I G CHARACTERISTICS TYPICAL PERFOR A CE CHARACTERISTICS Supply Current vs Sampling Frequency Supply Current vs Temperature Sleep Current vs Temperature SAMPLING FREQUENCY (kHz) 0.1 1 10 100 1000 0.01 1 10 1000 1860L/61L G01 0.1 100 TEMPERATURE ( °C) –50 600 500 400 300 200 100 0 25 75 1860L/61L G02 –25 0 50 100 125 TEMPERATURE ( °C) –50 20 15 10 5 0 25 75 1860L/61L G03 –25 0 50 100 125 fS = 150kHz VCC = 2.7V VREF = 2.5V CONV LOW = 1.5 µs TA = 25°C VCC = 2.7V fS = 150kHz VCC = 2.7V VREF = 2.5V Note 1: Absolute Maximum Ratings are those values beyond which the life of a device may be impaired. Note 2: All voltage values are with respect to GND. Note 3: Integral nonlinearity is defined as deviation of a code from a straight line passing through the actual endpoints of the transfer curve. The deviation is measured from the center of the quantization band. Note 4: Channel leakage current is measured while the part is in sample mode. Note 5: Assumes fSCK = fSCK(MAX). In the case of the LTC1860L SCK does not have to be clocked during this time if the SDO data word is not desired. In the case of the LTC1861L a minimum of 2 clocks are required on the SCK input after CONV falls to configure the MUX during this time. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |