| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
093.48 Datasheet(PDF) 14 Page - Finder Relays, Inc. |
|
|
|||||||||||||||||||||||||||||
093.48 Datasheet(HTML) 14 Page - Finder Relays, Inc. |
|
14 / 20 page ![]() B Technical data - Solid State Relays Other data 38.81/38.91 38.31/38.41 Power lost to the environment without output current W 0.25 (24 V DC) 0.5 with rated current W 0.4 2.2 (DC output)/3 (AC output) Terminals 38.81 38.91 Wire strip length mm 10 10 Screw torque Nm 0.5 — Max. wire size solid cable stranded cable solid cable stranded cable mm2 1 x 2.5 / 2 x 1.5 1 x 2.5 / 2 x 1.5 1 x 2.5 1 x 2.5 AWG 1 x 14 / 2 x 16 1 x 14 / 2 x 16 1 x 14 1 x 14 38.31 38.41 Wire strip length mm 10 10 Screw torque Nm 0.5 — Max. wire size solid cable stranded cable solid cable stranded cable mm2 1 x 2.5 / 2 x 1.5 1 x 2.5 / 2 x 1.5 1 x 2.5 1 x 2.5 AWG 1 x 14 / 2 x 16 1 x 14 / 2 x 16 1 x 14 1 x 14 Input specifications - Solid State Relays type 38.81 and 38.91 - 6.2 mm wide Input data DC Input data AC/DC Nominal voltage Supply code Operating range Release voltage Ratedcoil consumption Power consumption UN Umin Umax U I at UN P V V V V mA W 6 7.006 5 7.2 2.4 7 0.2 24 7.024 16.8 30 10 10.5 0.3 60 7.060 35.6 72 20 6.5 0.4 Nominal voltage Supply code Operating range Release voltage Ratedcoil consumption Power consumption UN Umin Umax U I at UN P V V V V mA VA/W 110…125 0.125 88 138 22 5.5* 0.7/0.7 220…240 0.240 184 264 44 3.5* 1/0.9 (*) Rated coil consumption and power consumption values relate to UN = 125 and 240 V. Input data - Leakage current suppression types Nominal voltage Supply code Operating range Release voltage Ratedcoil consumption Power consumption UN Umin Umax U I at UN P at UN V V V V mA W 110…125AC/DC 3.125 94 138 44 8(*) 1/1(*) 230…240 AC 3.240 184 264 72 6.5(*) 1.6/0.6(*) (*) Rated coil consumption and power consumption values relate to UN = 125 and 240 V. The 38 Series interface modules (supply version 3) have built-in leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110…125)V AC and (230…240)V AC. This problem can occur, for example, when connecting the interface modules to PLC‚s with triac outputs or when connecting via relatively long cables. Input specification - Solid State Relay types 38.31 and 38.41 - 14 mm wide Input data DC Input data AC/DC Nominal voltage Supply code Operating range Release voltage Ratedcoil consumption Power consumption UN Umin Umax U I at UN P V V V V mA W 12 7.012 9.6 18 5 9 0.2 24 7.024 16.8 30 5 12 0.3 Nominal voltage Supply code Operating range Release voltage Ratedcoil consumption Power consumption UN Umin Umax U I at UN P V V V V mA W 24 0.024 16.8 30 9 16.5 0.3 10 38 SERIES Relay interface modules - Technical data 38 SERIES |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |