MP2722 Datasheet(HTML) 21 Page - Monolithic Power Systems

Back Button MP2722 Datasheet HTML 17Page - Monolithic Power Systems MP2722 Datasheet HTML 18Page - Monolithic Power Systems MP2722 Datasheet HTML 19Page - Monolithic Power Systems MP2722 Datasheet HTML 20Page - Monolithic Power Systems MP2722 Datasheet HTML 21Page - Monolithic Power Systems MP2722 Datasheet HTML 22Page - Monolithic Power Systems MP2722 Datasheet HTML 23Page - Monolithic Power Systems MP2722 Datasheet HTML 24Page - Monolithic Power Systems MP2722 Datasheet HTML 25Page - Monolithic Power Systems Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 49 page
background image
MP2722
– 5A, SINGLE-CELL, I2C-CONTROLLED BUCK CHARGER W/ USB TYPE-C DRP
MP2722 Rev. 1.0
MonolithicPower.com
21
11/3/2022
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2022 MPS. All Rights Reserved.
The temperature conditions can be read in the
NTC1_FAULT and/or NTC2_FAULT bits. An
INT pulse is generated when NTC1 or NTC2
condition changes.
The NTC1 and NTC2 pins share the same
configurable thresholds Table 6 shows the
detection priority when the detection results
between the two NTC inputs are different.
Table 6: JEITA Detection Priority
NTC1
NTC2
Hot
Warm Normal
Cool
Cold
Hot
Hot
Hot
Hot
Hot
Hot
Warm
Hot
Warm
Warm
Warm
Cold
Normal
Hot
Warm Normal
Cool
Cold
Cool
Hot
Warm
Cool
Cool
Cold
Cold
Hot
Cold
Cold
Cold
Cold
For battery temperaure protection during boost
mode, if the NTC1_ACTION or NTC2_ACTION
bit is set to 1, the device compares the NTC1
and/or NTC2 pin voltage with the VCOLD and
VHOT thresholds. If the NTC pin voltage is
outside of VCOLD to VHOT range, then boost
mode is suspended. The NTC1_FAULT or
NTC2_FAULT bit is also set to report the
condition.
The preset hot, cold, warm, and cool voltage
thresholds are defined for a
β = 3435 thermistor.
It is recommended to use a pull-up resistor with
a value that matches the thermis
tor’s resistance
at 25°C.
Figure 5 shows the JEITA voltage/current
regulations
with
the
following
set-up:
NTC1_ACTION = 1, NTC2_ACTION = 0,
WARM_ACT
=
01,
COOL_ACT
=
10,
JEITA_VSET = 00, and JEITA_ISET = 00.
Charge Current
Charge Voltage
Cold
Cool
Warm
Hot
50% of ICC
100mV below
VBATT_REG
Normal
Figure 5: NTC Window under JEITA Control
Charging Safety Timer
The device has a built-in safety timer to prevent
an extended charging cycle due to abnormal
battery conditions. When VBATT is below the
VBATT_PRE threshold, the safety timer is fixed to 2
hours. When VBATT exceeds the VBATT_PRE
threshold, the safety timer is configured by
CHG_TIMER bits. When the CHG_TIMER bits
are set to 00, both the pre-charge timer and the
fast-charge timer are disabled.
Charging is disabled after safety timer expires.
Then the fault register
’s CHG_FAULT bit is set
to 10, and an INT pulse is generated.
During an input current, input voltage, thermal
regulation or JEITA cool/warm condition (when
charge
current
reduction
is
enabled),
the
charge timer counts at half of its usual rate.
This halved clock rate function can be disabled
by setting the EN_TMR2X bit to 0.
The charging safety timer resets if any of the
following conditions are met:
• The input source is unplugged
• EN_BUCK or EN_CHG is toggled
• The REG_RST bit is set
Remote Battery Voltage Sense
To minimize the parasitic trace resistance
during charging, the BATTSNS pin can be
connected to the actual battery pack
’s positive
terminal. Remote sensing of the battery voltage
accelerates the charging speed by helping the
charger stay in constant-current charge mode
for longer.
Shipping Mode
Entering Shipping Mode
When the host sets the BATTFET_DIS bit to 1,
the
MP2722
turns
off
the
BATTFET
immediately or after a delay time (tSHIP_DLY),
configured by the BATTFET_DLY bit.
Exiting Shipping Mode
When
the
MP2722
is
in
shipping
mode
(BATTFET_DIS = 1), either of the below events
can wake up the BATTFET:
• An input source is applied
• The RST
-------------
pin pulls low for tSHIPMODE



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com