10 sensing.honeywell.com
AC Series
Figure 10. MICRO SWITCH™ 22AC1
Figure 11. MICRO SWITCH™ 22AC2
Figure 12. MICRO SWITCH™ 22AC2-UL
6,35 mm
[0.25 in]
Ø 6,35 mm
[Ø 0.25 in]
6,75 mm
[0.266 in]
33,0 mm
[1.30 in]
10,31 mm ±0,25 mm
[0.406 in ±0.01 in]
12,7 mm
[0.50 in]
2X 6-32 UNC Thread
Ø 6,35 mm max.
[Ø 0.25 in max.]
Flexible insulator
3X 4-40 NC x 0.125 in round head
terminal screw and lockwasher
Positive overtravel stop is
provided on rod under spring
Ø 4,52 mm [Ø 0.178 in]
2,79 mm ±0,76 mm
[0.11 in ±0.03 in]
40,4 mm [1.59 in]
9,52 mm [0.375 in] max. free position
5,15 mm [0.203 in] min. operating position
3,17 mm [0.125 in] max. depressed position
47,7 mm [1.88 in]
31 mm
[1.22 in]
Push to operate-returns automatically
to position shown.
Pull to operate-remains in operated
position until reset for automatic return
by next full-stroke “push” operation
20,61 mm
[0.812 in]
4,8 mm [0.19 in]
2X 6-32 UNC Thread
V3-13 basic switch
13,2 mm ±0,76 mm
[0.52 in ±0.03 in]
6,73 mm ±0,25 mm
[0.265 in ±0.01 in]
5,53 mm ±0,25 mm
[0.218 in ±0.01 in]
Rivets flush or
underflush
4,54 mm ±0,25 mm
[0.179 in ±0.01 in]
6,35 mm [0.25 in]
Hole in bracket
Ø 6,35 mm
[Ø 0.25 in]
13,2 mm
[0.52 in]
33,0 mm
[1.30 in]
10,3 mm ±0,25 mm
[0.406 in ±0.01 in]
12,7 mm
[0.50 in]
4X 6-32 UNC Thread
4-40 UNC Thread
0.375 in min.
Ø 6,35 mm max.
[Ø 0.25 in max.]
Flexible insulator
3X 4-40 NC x 0.125 in round head
terminal screw and lockwasher
Positive overtravel stop is
provided on rod under spring
Ø 4,69 mm [Ø 0.185 in]
2,79 mm ±0,76 mm
[0.11 in ±0.03 in]
7,87 mm
[0.31 in]
40,44 mm [1.59 in]
9,52 mm [0.375 in] max. free position
5,15 mm [0.203 in] min. op. position
3,17 mm [0.125 in] max. depr. pos.
47,75 mm [1.88 in]
31,0 mm [1.22 in]
Push to operate-returns automatically
to position shown.
Pull to operate-remains in operated
position until reset for automatic return
by next full-stroke “push” operation
6,35 mm
[0.25 in]
Place label on
this surface
20,62 mm [0.812 in]
4,54 mm ±0,25 mm
[0.179 in ±0.01 in]
4,5 mm [0.17 in]
Ø 6,35 mm
[Ø 0.25 in]
13,21 mm ±0,76 mm
[0.52 in ±0.03 in]
33,0 mm
[1.30 in]
10,31 mm ±0,25 mm
[0.406 in ±0.01 in]
12,7 mm
[0.50 in]
2X 6-32 UNC Thread
4-40 UNC-2B Thread
X 0.375 in min.
Ø 6,35 mm max.
[Ø 0.25 in max.]
4X Flexible insulator
Positive overtravel stop is
provided on rod under spring
Ø 4,52 mm
[Ø 0.178 in]
2,79 mm ±0,76 mm
[0.11 in ±0.03 in]
50,8 mm [2.00 in]
9,53 mm [0.375 in] max. free position
5,16 mm [0.203 in] min. op. position
3,175 mm [0.125 in] max. depr. pos.
47,75 mm [1.88 in]
30,98 mm [1.22 in]
Push to operate-returns automatically
to position shown.
Pull to operate-remains in operated
position until reset for automatic return
by next full-stroke “push” operation
6,35 mm
[0.25 in]
20,62 mm
[0.812 in]
4,5 mm ±0,25 mm
[0.179 in ±0.01 in]
4,83 mm [0.19 in]
6,73 mm ±0,25 mm
[0.265 in ±0.01 in]
Rivets flush or
underflush
8,51 mm
[0.335 in]
3X 4-40 UNC X 0.125 in
round head terminal screws
and lockwashers
2X 6-32 UNC Thread
5,54 mm ±0,25 mm
[0.218 in ±0.01 in]
V3-3013 Basic switch