5 / 8 page ![]() REV. A –5– TMP17 If greater accuracy is desired, initial calibration and scale factor errors can be removed by using the TMP17 in the circuit of Figure 5. – VOUT = 100mV/ C + – TMP17 + V– OP196 REF43 +5V 8.66k 7.87k R1 1k 97.6k R2 5k Figure 5. Two Temperature Trim Circuit With the transducer at 0 C, adjustment of R1 for a 0 V output nulls the initial calibration error and shifts the output from K to C. Tweaking the gain of the circuit at an elevated temperature by adjusting R2 trims out scale factor error. The only error remaining over the temperature range being trimmed for is nonlinearity. A typical plot of two trim accuracy is given in Figure 6. TEMPERATURE – C 0.2 0.1 –0.3 –40 105 –25 025 75 0 –0.1 –0.2 Figure 6. Typical Two Trim Accuracy SUPPLY VOLTAGE AND THERMAL ENVIRONMENT EFFECTS The power supply rejection characteristics of the TMP17 mini- mize errors due to voltage irregularity, ripple, and noise. If a supply is used other than 5 V (used in factory trimming), the power supply error can be removed with a single temperature trim. The PTAT nature of the TMP17 will remain unchanged. The general insensitivity of the output allows the use of lower cost unregulated supplies and means that a series resistance of several hundred ohms (e.g., CMOS multiplexer, meter coil resistance) will not degrade the overall performance. The thermal environment in which the TMP17 is used determines two performance traits: the effect of self-heating on accuracy and the response time of the sensor to rapid changes in temperature. In the first case, a rise in the IC junction temperature above the ambient temperature is a function of two variables: the power consumption level of the circuit and the thermal resistance between the chip and the ambient environment ( JA). Self-heating error in °C can be derived by multiplying the power dissipation by JA. Because errors of this type can vary widely for surroundings with different heat sinking capacities, it is necessary to specify JA under several conditions. Table I shows how the magnitude of self-heating error varies relative to the environment. In typical free air applications at 25 C with a 5 V supply, the magnitude of the error is 0.2 C or less. A small glued-on heat sink will reduce the temperature error in high temperature, large supply voltage situations. Table I. Thermal Characteristics Medium JA ( C/W) (sec) * Still Air 158 52 Moving Air @ 500 FPM 60 10 Fluorinert Liquid 35 2 * is an average of one time constant (63.2% of final value). In cases where the thermal response is not a simple exponential function, the actual thermal response may be better than indicated. Response of the TMP17 output to abrupt changes in ambient temperature can be modeled by a single time constant expo- nential function. TPC 2 and TPC 3 show typical response time plots for media of interest. The time constant, , is dependent on JA and on the thermal capacities of the chip and the package. Table I lists the effective (time to reach 63.2% of the final value) for several different media. Copper printed circuit board connections will sink or conduct heat directly through the TMP17’s soldered leads. When faster response is required, a thermally conductive grease or glue between the TMP17 and the surface temperature being measured should be used. MOUNTING CONSIDERATIONS If the TMP17 is thermally attached and properly protected, it can be used in any temperature measuring situation where the maxi- mum range of temperatures encountered is between –40 C and +105 C. Thermally conductive epoxy or glue is recommended under typical mounting conditions. In wet environments, conden- sation at cold temperatures can cause leakage current related errors and should be avoided by sealing the device in nonconductive epoxy paint or conformal coating. APPLICATIONS Connecting several TMP17 devices in parallel adds the currents through them and produces a reading proportional to the average temperature. TMP17s connected in series will indicate the lowest temperature, because the coldest device limits the series current flowing through the sensors. Both of these circuits are depicted in Figure 7. + – + – + – TMP17 +5V 333.3 (0.1%) VT AVG (1mV/1K) + – + – + – 10k (0.1%) VT AVG (10mV/1K) +15V TMP17 TMP17 TMP17 Figure 7. Average and Minimum Temperature Connections |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |