21 / 28 page ![]() 21 ALQ07 DC-DC Converter Technical Reference Notes DATE: Aug., 9, 2003 Design Consideration Typical Application Cin: Recommended input capacitor 47uF, aluminum electrolytic type Cout: Recommended output capacitor 220uF, Tantalum type, each capacitor ESR<100mΩ C1,C2: Recommended 0.1uF ceramic capacitor Note: Io1+Io2≤10A Fusing The ALQ07 power modules have no internal fuse. An external fuse must always be employed! To meet international safety requirements, a 250 Volt rated fuse should be used. If one of the input lines is connected to chassis ground, then the fuse must be placed in the other input line. Standard safety agency regulations require input fusing. Recommended fuse rating for the ALQ07 Series is 2A. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|