| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
M48T201V Datasheet(PDF) 18 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M48T201V Datasheet(HTML) 18 Page - STMicroelectronics |
|
18 / 35 page ![]() Clock operation M48T201Y, M48T201V 18/35 3.5 Setting the alarm clock Registers 7FFF6h-7FFF2h contain the alarm settings. The alarm can be configured to go off at a prescribed time on a specific month, day of month, hour, minute, or second or repeat every month, day of month, hour, minute, or second. It can also be programmed to go off while the M48T201Y/V is in the battery back-up to serve as a system wake-up call. Bits RPT5-RPT1 put the alarm in the repeat mode of operation. Table 6 shows the possible configurations. Codes not listed in the table default to the once per second mode to quickly alert the user of an incorrect alarm setting. Note: User must transition address (or toggle chip enable) to see Flag Bit change. When the clock information matches the alarm clock settings based on the match criteria defined by RPT5-RPT1, the AF (Alarm Flag) is set. If AFE (Alarm Flag Enable) is also set, the alarm condition activates the IRQ/FT pin. To disable alarm, write ’0’ to the Alarm-Date register and RPT1-5. The IRQ/FT output is cleared by a READ to the Flags Register as shown in Figure 7. A subsequent READ of the Flags Register is necessary to see that the value of the Alarm Flag has been reset to '0.' The IRQ/FT pin can also be activated in the battery back-up mode. The IRQ/FT will go low if an alarm occurs and both ABE (Alarm in Battery Back-up Mode Enable) and AFE are set. The ABE and AFE Bits are reset during power-up, therefore an alarm generated during power-up will only set AF. The user can read the Flag Register at system boot-up to determine if an alarm was generated while the M48T201Y/V was in the deselect mode during power-up. Figure 8 on page 19 illustrates the back-up mode alarm timing. Figure 7. Alarm interrupt reset waveforms Table 6. Alarm repeat modes RPT5 RPT4 RPT3 RPT2 RPT1 Alarm setting 1 1 1 1 1 Once per Second 1 1 1 1 0 Once per Minute 1 1 1 0 0 Once per Hour 11 00 0 Once per Day 1 0 0 0 0 Once per Month 00 00 0 Once per Year AI02331 A0-A18 ACTIVE FLAG BIT ADDRESS 7FFF0h IRQ/FT 15ns Min HIGH-Z |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |