27 / 36 page ![]() VIPer53 - E Transconductance error amplifier 27/36 The lowest load gives another condition for stability: The frequency FBW1 must not encounter the second order slope generated by the load pole and the integrator part of the error amplifier. This condition can be met by adjusting the CCOMP value: Equation 13 The above formula gives a minimum value for CCOMP. It can be then increased to provide a natural soft start function as this capacitor is charged by the error amplifier current capacity ICOMPhi at start-up. Figure 22. Typical compensation network C COMP R L1 C OUT ⋅ 6.3 Gm R COMP 2 ⋅⋅ ------------------------------------------------------ P OUT1 P MAX ------------------- ⋅ > P OUT1 V OUT 2 R L1 --------------- = With: 15V VDD OSC DRAIN SOURCE COMP TOVL Rcomp Ccomp 10nF |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|