| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
EP11 Datasheet(PDF) 21 Page - Power Integrations, Inc. |
|
|
|||||||||||||||||||||||||||||
EP11 Datasheet(HTML) 21 Page - Power Integrations, Inc. |
|
21 / 46 page ![]() EPR-00011 - 70 W adapter 22-Jan-01 Page 21 of 46 Power Integrations Inc Tel: +1 408 523 9200 Fax: +1 408 523 9300 www: http://www.powerint.com Figure 11 - Location of board mounted thermocouples The tests were run at an input line voltage of 90 Volts (60Hz). The load was adjusted to provide a nominal output power at the end of a cable of first 60 Watts, then 65 Watts, 70 Watts, and finally 72.5 Watts. Power at the power supply output connector (J2) was approximately; 61.2 Watts, 66.2 Watts, 70.6 Watts and 73.8 Watts respectively. The maximum case surface temperature was < 75 °C in a 40°C ambient, 90 V AC, 70W (see figure 14 for thermal image) 1 2 3 4 5 8 9 10 9 11 |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |