| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
Z-BHASA/24 Datasheet(PDF) 8 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
Z-BHASA/24 Datasheet(HTML) 8 Page - List of Unclassifed Manufacturers |
|
8 / 10 page ![]() 590 A Ad dd d-o on n R Re essiid du ua all C Cu urrrre en ntt P Prro otte eccttiio on n U Un niitt P PB BH HT T • By combination with miniature circuit breaker PLHT => RCBO-Unit (MCCB) • Add-on residual current unit (screw connection) for 80 or 125 A (2-pole and 4-pole) • High flexibility and ease of installation thanks to variable wiring (400 mm flexible connection wires 2p = 2 units, 4p = 4 units included in the set) • Free selection of main power supply • Auxiliary switch 1 NO included as standard in all PBHT versions • Permits combinations with a variety of characteristics thanks to the different rated currents and characteristics of the miniature circuit breakers PLHT which can be connected • For trade and industry applications • For subsequent mounting onto 2, 3, 3+N and 4-pole-miniature circuit break- ers PLHT • Toggle (serves as switch position- and tripping indicator) • The screw connection to the PLHT-device can be unscrewed at any time. Consequently, in case of modifications of the systems to be protected, the installation can be adapted to new requirements at any time. A Acccce esssso orriie ess:: Flexible connection wires (connection to PLHT) are included in the standard set: 2-pole 80A 2 x 16mm2 (400mm each) 4-pole 80A 4 x 16mm2 (400mm each) 2-pole 125A 2 x 35mm2 (400mm each) 4-pole 125A 4 x 35mm2 (400mm each) E Elle eccttrriicca all Design according to IEC/EN 60947-2 Current test marks as printed onto the device C Cu urrrre en ntt ffllo ow w p pa atth hss Rated voltage U e 230/400 V AC Operational voltage range 196-440 V Rated frequency 50 Hz Rated current I n 80 A, 125 A Rated tripping current I∆n 30, 300, 500, 1000 mA Rated non-tripping current I∆no 0.5 I∆n Sensitivity AC and pulsating DC Tripping characteristic instantaneous 250A (8/20µ), surge current-proof; Type S 40 ms delay 6kA (8/20µ) with selective disconnecting function, surge current-proof Rated service short circuit breaking capacity I cn same as connected PLHT Rated ultimate circuit breaking capacity I cu same as connected PLHT Rated fault short circuit breaking capacity I∆/n = I cu Rated peak withstand voltage U imp 4 kV (1.2/50µ) Endurance mechanical comp. PBHT-80 >10000 PBHT-125 >8000 Endurance electrical comp. PBHT-80 >1500 PBHT-125 >1000 A Au uxxiilliia arryy C Co on ntta acctt Utilisation category AC15 Rated voltage U e 250 V AC Rated operational current I e 16 A AC M Me ecch ha an niicca all Frame size 45 mm Device height 90 mm Device width 95 mm (5,5MU) Depth of central body 60 mm Mounting screwed onto PLHT 2-, 3-, 4-pole; PBHT-ASA Upper and lower terminals lift terminals Terminal protection finger and hand touch safe, BGV A3, ÖVE-EN 6 Terminal capacity Main conductor 2.5 - 50 mm2 Auxiliary switch 1 - 25 mm2 Degree of protection, built-in IP40 Permissible ambient temperature range -25°C to +40°C Resistance to climatic conditions acc. to IEC 60068-2 (25...55°C/90...95% relative humidity) Dimensions (mm) PBHT/2p + PLHT/2p PBHT/4p + PLHT/3p+N PBHT/4p + PLHT/3p PBHT/4p + PLHT/4p Connection diagrams 2-pole 4-pole Technical Data Protective Devices SG_Technik_MV_E.qxd 25.04.2005 10:48 Seite 590 |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |