Motor de Búsqueda de Datasheet de Componentes Electrónicos
  Spanish  ▼
ALLDATASHEET.ES

X  

TPS274C65CP Datasheet(PDF) 24 Page - Texas Instruments

No. de pieza TPS274C65CP
Descripción Electrónicos  TPS274C65CP 72mΩ Quad-Channel Smart High-Side Switch With Diagnostics
PDF  39 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrónico  TI1 [Texas Instruments]
Página de inicio  http://www.ti.com
Logo TI1 - Texas Instruments

TPS274C65CP Datasheet(HTML) 24 Page - Texas Instruments

Back Button TPS274C65CP_V02 Datasheet HTML 20Page - Texas Instruments TPS274C65CP_V02 Datasheet HTML 21Page - Texas Instruments TPS274C65CP_V02 Datasheet HTML 22Page - Texas Instruments TPS274C65CP_V02 Datasheet HTML 23Page - Texas Instruments TPS274C65CP_V02 Datasheet HTML 24Page - Texas Instruments TPS274C65CP_V02 Datasheet HTML 25Page - Texas Instruments TPS274C65CP_V02 Datasheet HTML 26Page - Texas Instruments TPS274C65CP_V02 Datasheet HTML 27Page - Texas Instruments TPS274C65CP_V02 Datasheet HTML 28Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 39 page
background image
Condition
VS
VDD
ENx
OUTx
DIAG_EN
LATCH
VS_FAULT
STx
FAULT
Recovery
VS
Undervoltag
e
< VS_UVP
> VDD,UVLO
X
X
X
X
L
H
-
Normal
> VS_UVP
> VDD,UVLO
L
L
X
X
H
H
-
> VS_UVP
> VDD,UVLO
H
H
X
X
H
H
-
OFF-state
Short to
Supply,
OFF-state
open load
> VS_UVP
> VDD,UVLO
L
H
H
X
H
L
-
Short to
GND,
Overload,
TSD
> VS_UVP
> VDD,UVLO
H
L
X
L
H
L
Auto-retry
> VS_UVP
> VDD,UVLO
H
L
X
H
H
L
Latch-off.
Fault
recovers
when ENx
toggles.
8.3.4.2 Short-to-Battery and Open-Load Detection
The TPS274C65CP is capable of detecting short-to-battery and open-load events when the switch is in the OFF
state if the DIAG_EN is high. The fault will be report to STx pin. The feature can be turned off by pulling the
DIAG_EN pin low. The detection threshold will be when VOUT > VWB_OFF_TH.
VOUT
VWB_OFF_TH
Load
Fault
Register
TPS274C65CP
VS
OUT
FLT
6.7 V
Figure 8-15. Open-Load Detection Circuit
8.4 Device Functional Modes
During typical operation, the TPS274C65CP can operate in a number of states that are described below.
8.4.1 Off
OFF state occurs when the device is not powered.
8.4.2 Active
In ACTIVE state, the switch is enabled with ENx high. The diagnostic functions can be either on or off during
ACTIVE state.
TPS274C65CP
SLVSH35A – OCTOBER 2023 – REVISED FEBRUARY 2024
www.ti.com
24
Submit Document Feedback
Copyright © 2024 Texas Instruments Incorporated
Product Folder Links: TPS274C65CP



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com