| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
IDT723666 Datasheet(PDF) 12 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
IDT723666 Datasheet(HTML) 12 Page - Renesas Technology Corp |
|
12 / 40 page ![]() 12 IDT723656/723666/723676 CMOS TRIPLE BUS SyncFIFOTM WITH BUS MATCHING 2,048 x 36 x 2, 4,096 x 36 x 2 and 8,192 x 36 x 2 COMMERCIALTEMPERATURERANGE FS2 FS1/SEN FS0/SD MRS1 MRS2 X1 AND Y1 REGlSTERS(1) X2 AND Y2 REGlSTERS(2) HH H ↑ X64 X HH H X ↑ X64 HH L ↑ X16 X HH L X ↑ X16 HL H ↑ X8 X HL H X ↑ X8 LH H ↑ X256 X LH H X ↑ X256 LL H ↑ X 1,024 X LL H X ↑ X 1,024 LH L ↑↑ Serial programming via SD Serial programming via SD HL L ↑↑ Parallel programming via Port A(3,5) Parallel programming via Port A(3,5) LL L ↑↑ IP Mode(4, 5) IP Mode(4, 5) Once the Master Reset (MRS1, MRS2) input is HIGH, a LOW on the BE/ FWFTinputduringthenextLOW-to-HIGHtransitionofCLKA(forFIFO1)and CLKC(forFIFO2)willselectFWFTmode. ThismodeusestheOutputReady function (ORA, ORB) to indicate whether or not there is valid data at the data outputs(A0-A35orB0-B17). ItalsousestheInputReadyfunction(IRA,IRC) toindicatewhetherornottheFIFOmemoryhasanyfreespaceforwriting. In theFWFTmode,thefirstwordwrittentoanemptyFIFOgoesdirectlytothedata outputs,noreadrequestnecessary. Subsequentwordsmustbeaccessedby performingaformalreadoperation. FollowingMasterReset,thelevelappliedtotheBE/FWFTinputtochoose thedesiredtimingmodemustremainstaticthroughoutFIFOoperation. Refer toFigure4(FIFO1MasterReset)andFigure5(FIFO2MasterReset)forFirst WordFallThroughselecttimingdiagrams. PROGRAMMING THE ALMOST-EMPTY AND ALMOST-FULL FLAGS FourregistersintheseFIFOsareusedtoholdtheoffsetvaluesfortheAlmost- EmptyandAlmost-Fullflags. ThePortBAlmost-Emptyflag(AEB)Offsetregister islabeledX1andthePortAAlmost-Emptyflag(AEA)Offsetregisterislabeled X2. ThePortAAlmost-Fullflag(AFA)OffsetregisterislabeledY1andthePort CAlmost-Fullflag(AFC)OffsetregisterislabeledY2. Theindexofeachregister namecorrespondstoitsFIFOnumber. TheOffsetregisterscanbeloadedwith preset values during the reset of a FIFO, programmed in parallel using the FIFO’sPortAdatainputs,orprogrammedinserialusingtheSerialData(SD) input (see Table 1). FS0/SD, FS1/SEN and FS2 function the same way in both IDT Standard and FWFT modes. — PRESET VALUES ToloadaFIFO’sAlmost-EmptyflagandAlmost-FullflagOffsetregisterswith oneofthefivepresetvalueslistedinTable1,theflagselectinputsmustbeHIGH orLOWduringamasterreset. Forexample,toloadthepresetvalueof64into X1andY1,FS0,FS1andFS2mustbeHIGHwhenFlFO1reset(MRS1)returns HIGH. FlagOffsetregistersassociatedwithFIFO2areloadedwithoneofthe preset values in the same way with FIFO2 Master Reset (MRS2) toggled simultaneouslywithFIFO1MasterReset(MRS1). ForrelevantPresetvalue loading timing diagrams, see Figure 4 and 5. — PARALLEL LOAD FROM PORT A ToprogramtheX1,X2,Y1,andY2registersfromPortA,performaMaster Reset on both FlFOs simultaneously with FS2 HIGH or LOW, FS0 and FS1 LOWduringtheLOW-to-HIGHtransitionofMRS1andMRS2. ThestateofFS2 atthispointofresetwilldeterminewhethertheparallelprogrammingmethodhas Interspersed Parity or Non-Interspersed Parity. Refer to Table 1 for Flag Programming Flag Offset setup . It is important to note that once parallel programming has been selected during a Master Reset by holding both FS0 & FS1 LOW, these inputs must remain LOW during all subsequent FIFO operation. They can only be toggled HIGH when future Master Resets are performedandotherprogrammingmethodsaredesired. Afterthisresetiscomplete,thefirstfourwritestoFIFO1donotstoredatain RAM but load the Offset registers in the order Y1, X1, Y2, X2. For Non- InterspersedParitymodethePortAdatainputsusedbytheOffsetregistersare (A10-A0), (A11-A0), or (A12-A0) for the IDT723656, IDT723666, or IDT723676,respectively. ForInterspersedParitymodethePortAdatainputs usedbytheOffsetregistersare(A11-A9,A7-A0),(A12-A9,A7-A0),or(A13- A9,A7-A0)fortheIDT723656,IDT723666,orIDT723676,respectively. The highestnumberedinputisusedasthemostsignificantbitofthebinarynumber ineachcase. Validprogrammingvaluesfortheregistersrangefrom1to2,044 for the IDT723656; 1 to 4,092 for the IDT723666; and 1 to 8,188 for the IDT723676. AfteralltheOffsetregistersareprogrammedfromPortA,thePort CFull/InputReadyflag(FFC/IRC)issetHIGH,andbothFIFOsbeginnormal operation. Refer to Figure 8 for a timing diagram illustration for parallel programmingoftheflagoffsetvalues. INTERSPERSED PARITY InterspersedParityisselectedduringaMasterResetoftheFIFO. Referto Table1fortheset-upconfigurationofInterspersedParity. TheInterspersed Parityfunctionallowstheusertoselectthelocationoftheparitybitsintheword loadedintotheparallelport(A0-An)duringprogrammingoftheflagoffsetvalues. TABLE 1 — — — — — FLAG PROGRAMMING NOTES: 1. X1 register holds the offset for AEB; Y1 register holds the offset for AFA. 2. X2 register holds the offset for AEA; Y2 register holds the offset for AFC. 3. When this method of parallel programming is selected, Port A will assume Non-Interspersed Parity. 4. When IP Mode is selected, only parallel programming of the offset values via Port A, can be performed and Port A will assume Interspersed Parity. 5. IF parallel programming is selected during a Master Reset, then FS0 & FS1 must remain LOW during FIFO operation. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |