7 / 22 page ![]() 32 Direct acting 2 port solenoid valve for compressed air, manifold (special purpose valve) GFAB Series NC (normally closed) type Port size: M5, Rc1/8, Rc1/4, Rc3/8 Common specifications Descriptions Compressed air 0 to 1.4 (Refer to the maximum working pressure differential on the individual specifications) 2.1 (1.5 for GFAB11/GFAB21) AC: -10 to 60, DC: -10 to 40 (no freezing) AC: -20 to 40, DC: -20 to 40 B No corrosive gas and flammable Direct acting poppet structure 0.2 or less Free IP65 or equivalent (Note 1) 1 1.5 1.5 2 2 3 5 3 4 7 4 5 7 0.15 0.31 0.31 0.53 0.55 1.2 2.1 1.2 2.1 3.5 2.1 3.0 4.4 0.54 0.49 0.49 0.38 0.48 0.39 0.27 0.39 0.34 0.21 0.34 0.22 0.18 0.7 0.3 1.0 0.6 1.4 1.0 0.3 1.4 1.0 0.25 1.2 0.7 0.3 0.7 0.3 1.0 0.6 1.4 0.6 0.15 1.4 0.9 0.15 1.2 0.8 0.3 GFAB MPa MPa cm3/min. (ANR) Individual specifications GFAB -Z -1 GFAB -1 -2 GFAB -2 -3 -6 GFAB -3 -5 -7 GFAB -5 -6 -7 Port size Port A Port C Orifice (mm) AC DC 50Hz 3.4 5.3 7.5 15 20 Voltage Model no. GFAB1 GFAB2 GFAB3/4/5 2mA or less 3mA or less 6mA or less 1mA or less 1.5mA or less 3mA or less 1mA or less 2mA or less 100 VAC 200 VAC 24 VDC 12 VDC 1.0 1.4 2.6 5.0 4.6 2.3/1.6 Rc 1/8 Rc 1/4 M5 Rc 1/4 Rc 1/4 Rc 1/8 Rc 1/8 Rc 3/8 Rc 3/8 Rc 3/8 100 VAC 50/60Hz 110 VAC 60Hz 200 VAC 50/60Hz 220 VAC 60Hz 24 VDC 12 VDC 3 3.7 10 9 2.7/2 4 5.5 20 17 4/3.4 6.5 11 40 35 7.5/6.5 8 16 55 45 11/9.5 11.5 60Hz 50Hz 60Hz AC 50/60Hz DC Max. working pressure MPa Rated voltage Power consumption (W) At holding At starting Max. working pressure differential MPa Rated electric power (VA) Descriptions Model no. Working fluid Working pressure differential range Withstanding pressure (water pressure) Fluid temperature Ambient temperature Heat proof class Atmosphere Valve structure Valve seat leakage Installation attitude Protective structure *1: Use the allowable voltage fluctuation range within 10% of the rated voltage. *2: The leakage current must be less than values given below. *3: Effective sectional area S and sonic conductance C are converted as S 5.0 x C. IN OUT Port A Port C Port A IN OUT IN OUT IN OUT Port A Port A Port C JIS symbol NC (normally closed) / common supply type (Port C pressurized) NC (normally closed) / individual supply type (Port A pressurized) 11 15 21 25 31 35 41 45 51 55 C[dm3/(s bar)] b Flow characteristics Note 1: The T-type terminal box type is IP61 or equivalent, and the GFAB11/GFAB15 compact terminal box type is IP40 or equivalent. Refer to Ending 17 for more details. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |