| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
DSP56307/D Datasheet(PDF) 10 Page - Motorola, Inc |
|
|
|||||||||||||||||||||||||||||
DSP56307/D Datasheet(HTML) 10 Page - Motorola, Inc |
|
10 / 156 page ![]() 1-4 DSP56307 Technical Data MOTOROLA Signals/Connections Ground GROUND Table 1-3 Grounds Ground Name Description GNDP PLL Ground ÑGNDP is ground-dedicated for PLL use. The connection should be provided with an extremely low-impedance path to ground. VCCP should be bypassed to GNDP by a 0.47 µF capacitor located as close as possible to the chip package. GNDP1 PLL Ground 1 ÑGNDP1 is ground-dedicated for PLL use. The connection should be provided with an extremely low-impedance path to ground. GNDQ Quiet Ground ÑGNDQ is an isolated ground for the internal processing logic. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. GNDA Address Bus Ground ÑGNDA is an isolated ground for sections of the address bus I/O drivers. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. There are four GNDA connections. GNDD Data Bus Ground ÑGNDD is an isolated ground for sections of the data bus I/O drivers. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. GNDC Bus Control Ground ÑGNDC is an isolated ground for the bus control I/O drivers. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. GNDH Host Ground ÑGNDH is an isolated ground for the HI08 I/O drivers. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. GNDS ESSI, SCI, and Timer Ground ÑGNDS is an isolated ground for the ESSI, SCI, and timer I/O drivers. This connection must be tied externally to all other chip ground connections. The user must provide adequate external decoupling capacitors. Not Recommended for New Design |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |