20 / 64 page ![]() 20 Installing the LED Unit (with Removable Contact Block) Align the to of the LED unit with the TOP marking on the contact block. Push the LED unit into the contact block. Wiring 1. The applicable wire size is 1.25 mm2 maximum. 2. Solder the terminal at a temperature of 310 to 350°C within 3 seconds using a soldering iron. Sn-Ag-Cu type is recommended when using lead-free solder. When solder- ing, do not touch the enabling switch with the soldering iron. Also ensure that no tensile force is applied to the ter- minal. Do not bend the terminal or apply excessive force to the terminal. 3. Use a non-corrosive rosin flux. 4. Because the terminal spacing is narrow, use protective tubes or heat shrinkable tubes to avoid burning of wire coating or short circuit. Solder/Tab Terminal #110 1. Use #110 receptacles for 0.5mm-thick tabs. 2. Because the terminal spacing is narrow, use protective tubes or heat shrinkable tubes of 0.5mm minimum in thickness. 3. Do not apply force on the terminals in the direction other than vertical to the mounting panel, otherwise the terminals will be damaged. PC Board Terminal 1. When mounting a contact block on a PC board, provide sufficient rotating space for the PC board when installing and removing the contact block. 2. When mounting an XA emergency stop switch on a PC board, make sure that the operator is securely installed. About PC Board and Circuit Design 1. Use PC boards made of glass epoxy copper-clad laminated sheets of 1.6 mm in thickness, with double-sided through hole. 2. PC boards and circuits must withstand rated voltage and current, including the instantaneous current and voltage at switching. 3. The minimum applicable load is 5V AC/DC, 1 mA. This value may vary according to the operating environment and load. 4. Within the 2.8 ∗ mm areas shown in the figure below, terminals touch the PC board, resulting in possible short circuit on the printed circuit. When designing a PC board pattern, take this possibility into consideration. Installing Insulation Terminal Cover To install the terminal cover (XA9Z-VL2), align the TOP marking on the terminal cover with TOP marking on the contact block, and press the terminal cover toward the contact block. Note: For wiring, insert the wires into the holes in the terminal cover before soldering. Contact Bounce When the button is reset by pulling or turning, the NC main contacts will bounce. When pressing the button, the NO monitor contacts will bounce. When designing a control circuit, take the contact bounce time into consideration (reference value: 20 ms). Nameplate When anti-rotation is not required, remove the projection from the nameplate using pliers. Projection Nameplate Handling Do not expose the switch to excessive shock and vibration, otherwise the switch may be deformed or damaged, causing malfunction or operation failure. TOP side 19.8 8.7 (0.5) 1.6 (PC Board) (0.5) 10-ø1.2 holes Solder Surface Surface for installing components 2.8∗ 2.8∗ Solder Surface Surface for installing components All dimensions in mm. ø16 XA Series Emergency Stop Switches (w/Removable Contact Block) |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |