4 / 16 page ![]() 4 MOR SERIES 120 WATT DC/DC CONVERTERS DUAL OUTPUT MODELS MOR286R3D MOR289R5D MOR2812D MOR2815D PARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS OUTPUT VOLTAGE5 +VOUT 6.24 6.30 6.36 9.40 9.50 9.60 11.88 12.00 12.12 14.85 15.00 15.15 VDC –VOUT 6.20 6.30 6.40 9.35 9.50 9.65 11.80 12.00 12.20 14.76 15.00 15.24 OUTPUT CURRENT6 VIN = 16 to 40 VDC — ±8 16 — ±5.53 11.05 — ±4.58 9.16 — ±4.00 8.00 A6 OUTPUT POWER VIN = 16 to 40 VDC — — 100 — — 105 — — 110 — — 120 W OUTPUT RIPPLE 10 kHz - 20 MHz VOLTAGE Tc = –55°C to +125°C — 50 100 — 75 120 — 75 120 — 75 150 mV p-p +VOUT / –VOUT 10 kHz - 2 MHz Tc = –55°C to +125°C — 30 60 — 50 80 — 50 100 — 50 120 LINE REGULATION +VOUT — 25 50 — 25 50 — 25 50 — 25 50 mV VIN = 16 to 40 VDC –VOUT — 50 160 — 50 100 — 50 100 — 50 100 LOAD REGULATION +VOUT — 25 50 — 25 50 — 25 50 — 25 50 mV –VOUT — 50 200 — 50 200 — 50 200 — 50 200 CROSS REGULATION7 NEGATIVE VOUT — 5 8 — 47 — 3 5 — 24 % INPUT VOLTAGE CONTINUOUS 16 28 40 16 28 40 16 28 40 16 28 40 VDC TRANSIENT 120 msec — — 50 — — 50 — — 50 — — 50 V INPUT CURRENT NO LOAD — 70 140 — 70 140 — 70 140 — 70 140 mA FULL LOAD — — 4.45 — — 4.63 — — 4.72 — — 5.10 A INHIBITED - INH1 — — 10 — — 10 — — 10 — — 10 mA INHIBITED - INH2 — — 70 — — 70 — — 70 — — 70 INPUT RIPPLE 10 kHz - 20 MHz CURRENT Tc = –55°C to +125°C — — 130 — — 130 — — 130 — — 130 mA p-p EFFICIENCY 81 83 — 82 84 — 84 86 — 85 87 — % LOAD FAULT1 POWER DISSIPATION OVERLOAD — — 30 — — 30 — — 30 — — 30 W SHORT CIRCUIT2 — — 24 — — 24 — — 22 — — 20 RECOVERY — — 10 — — 10 — — 10 — — 10 ms OUTPUT CURRENT TRIP POINT — — 20 — — 14 — — 11 — — 10 A SHORT CIRCUIT2 — — 19 — — 13 — — 10 — — 9 STEP LOAD RESP. 50% – 100% — 50% ±VOUT TRANSIENT — — 500 — — 500 — — 600 — — 600 mV pk RECOVERY3 — — 300 — — 300 — — 300 — — 300 µs STEP LINE RESP. 16 – 40 – 16 VDC ±VOUT TRANSIENT4 — — 500 — — 600 — — 600 — — 750 mV pk RECOVERY3 — — 300 — — 300 — — 300 — — 300 µs START-UP TIME — — 10 — — 10 — — 10 — — 10 ms OVERSHOOT — — 50 — — 50 — — 50 — — 50 mV pk INHIBIT PIN CURRENT UNIT INHIBITED — 0.1 1.0 — 0.1 1.0 — 0.1 1.0 — 0.1 1.0 mA Electrical Characteristics: Tc = 25°C, full load, Vin = 28 VDC, free run, unless otherwise specified. Notes: 1. Load fault conditions are measured with a resistive load. 2. Short circuit is measured with a 10 m W (±10%) load. 3. Time to settle to within 1% of Vout. 4. Transition time > 10 µs 5. Output voltage for dual output models is measured at half load. 6. The maximum specification is the total output current/power. Up to 70% of that total is available from either output provided the other output maintains a minimum of 15% the total power used. 7. Cross regulation percentages are for the following conditions: +Po = 30% and –Po = 70% +Po = 10% and –Po = 50% +Po = 70% and –Po = 30% +Po = 50% and –Po = 10% |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |