TRM-915-R250 Datasheet(PDF) 16 Page - Linx Technologies |
|
|
|||||||||||||||||||||||||||||
TRM-915-R250 Datasheet(HTML) 16 Page - Linx Technologies |
|
16 / 39 page ![]() – – – – 26 27 Using the Command Response (CMD_RSP) Line The CMD_RSP line is normally high, but the module lowers this line when responding to a UART command. This indicates to an external processor that the data on the TXD line is a response to a command and not data received over-the-air. The module outputs received RF data immediately following the command response. The CMD_RSP line does rise before resuming RF data, but some processors cannot react quickly enough to this signal and may not able to separate the command responses from RF data. The regCMDHALT register controls the behavior of the TXD line when the CMD line is low and the external processor is configuring the module. If this register is set to 0x01 and the CMD line is low, the module stops outputting the RF data and internally buffers it. Once the CMD line is raised, the buffered RF data is output on the TXD line. This allows the external processor to have separate configuration times and data times instead of potentially having to handle both at once. The CMD Line The CMD line is used to inform the module where incoming UART data should be routed. When the line is high or left floating, all incoming UART data is treated as payload data and is routed to the transmitter to be sent over the air. If the CMD line is low, the incoming UART data is routed to the command parser for processing. Since the module’s controller looks at UART data one byte at a time, the CMD line must be held low for the entire duration of the command plus a 20µs margin for processing. Leaving the line low for additional time (for example, until the ACK byte is received by the application) does not adversely affect the module. If RF packets are received while the CMD line is active, they are still processed and output on the module’s UART. Figure 19 shows this timing. The CMD line is also used during the module startup process to determine whether or not to reload the non-volatile registers with factory defaults. The module startup process is executed when the module is powered on from an off state or is issued a software or hardware reset. When the module goes through this startup process, it checks the state of the CMD line. If it is low, the module clears the non-volatile registers and re-populates them with factory default values. It is important to ensure that CMD is held high or left floating during power-up under normal conditions. Possible reset sources that could cause the module to reboot are power supply brown-out, power supply instability and noise present on the RESET line, noise/voltage spikes on digital I/O lines, issuing a reset command through the command interface, and toggling the RESET line when not in deep sleep. RXD CMD 0xFF ...B1B0 ≥20µs Figure 19: 250 Series Transceiver CMD Line Timing |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |