| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
R5-TS1AS/Q Datasheet(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R5-TS1AS/Q Datasheet(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 4 page ![]() MODEL: R5-TS1A R5-TS1A SPECIFICATIONS ES-7571 Rev.8 Page 2/4 http://www.m-system.co.jp/ OUTPUT SPECIFICATIONS Operational range: Approx. 0 – 24 mA DC INSTALLATION Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R5-BS) Weight: 100 g (3.53 oz) PERFORMANCE Conversion accuracy Input: ±0.4°C (±0.6°C for C thermocouple) ±0.8°F (±1.1°F for C thermocouple) Output: ±0.1 % of the retransmitted range + input conversion accuracy (May exceed ± 0.1 % depending upon the input temperature range.) Conversion data: Temperature data scaled and converted into 0 – 100 % data and supplied to the internal network bus Data allocation: 1 Cold junction compensation error: ±0.5°C or ±0.9°F (at 20°C ±10°C or 68°F ±18°F) Temp. coefficient Input: ±0.015 %/°C (±0.008 %/°F) Output: ±0.02 %/°C (±0.01 %/°F) Response time: ≤ 0.4 sec. (0 – 90 %) Burnout response time: ≤ 2 sec. Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (input to output to internal bus or internal power) 2000 V AC @ 1 minute (power input to FG; isolated on the power supply module) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive EN 50581 FUNCTIONS • Zero/Span Adjustment Modes Monitor Mode Re-transmits the input signal as output in proportion. Output 0 % Adjustment Mode Adjusts the 0 % output signal using the front UP/DOWN buttons, in monitoring the output value with a multimeter. SW1 through SW3 switch the internal increments by 1, 5 and 10. Output 100 % Adjustment Mode Adjusts the 100 % output signal using the front UP/DOWN buttons, in monitoring the output value with a multimeter. SW4 through SW6 switch the internal increments by 1, 5 and 10. Simulated Output Mode Outputs the simulated signals of 0 %, 50 % and 100 %. • How to Operate 1) Start up in Monitor Mode (SW position = 0) and wait for 2 or 3 seconds. 2) Switch to another mode and go through the adjustments. 3) Reset the switch to the position ‘0’ so that the new setting is stored in the internal memory. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |