| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
ADM1266ACPZ-R7 Datasheet(PDF) 36 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM1266ACPZ-R7 Datasheet(HTML) 36 Page - Analog Devices |
|
36 / 62 page ![]() ADM1266 Data Sheet Rev. A | Page 36 of 62 VOUT_MARGIN_HIGH The VOUT_MARGIN_HIGH command sets the margin high voltage. Exponent N is set using VOUT_MODE[4:0]. Table 21. Register 0x25—VOUT_MARGIN_HIGH Bits Bit Name R/W Description [15:0] Mantissa Y R/W 16-bit unsigned Integer Y value for linear data format (V = Y × 2N). N is defined using VOUT_MODE[4:0]. VOUT_MARGIN_LOW The VOUT_MARGIN_LOW command sets the margin low voltage. Exponent N is set using VOUT_MODE[4:0]. Table 22. Register 0x26—VOUT_MARGIN_LOW Bits Bit Name R/W Description [15:0] Mantissa Y R/W 16-bit unsigned Integer Y value for linear data format (V = Y × 2N). N is defined using VOUT_MODE[4:0]. VOUT_SCALE_LOOP The VOUT_SCALE_LOOP command sets the gain (KR) by which the commanded voltage (VOUT) is scaled to generate the internal reference voltage (VREF). VREF = VOUT × KR, where KR = Y × 2N. Table 23. Register 0x29—VOUT_SCALE_LOOP Bits Bit Name R/W Description [15:11] Exponent N R/W Twos complement of Exponent N used in linear data format (X = Y × 2N). [10:0] Mantissa Y R/W Twos complement of Mantissa Y used in linear data format (X = Y × 2N). VOUT_SCALE_MONITOR The VOUT_SCALE_MONITOR command sets the gain (KVOUT) by which the sensed output voltage at the device under test (DUT) (VOUT_DUT) is scaled to generate the reading for the READ_VOUT command. READ_VOUT = VOUT_DUT × KVOUT, where KVOUT = Y × 2N. Table 24. Register 0x2A—VOUT_SCALE_MONITOR Bits Bit Name R/W Description [15:11] Exponent N R/W Twos complement of Exponent N used in linear data format (X = Y × 2N). [10:0] Mantissa Y R/W Twos complement of Mantissa Y used in linear data format (X = Y × 2N). VOUT_OV_FAULT_LIMIT The VOUT_OV_FAULT_LIMIT command sets the overvoltage threshold (in volts) measured at the sense/output pin, VHx/VPx, that causes an overvoltage fault condition. Exponent N is set using VOUT_MODE[4:0]. Table 25. Register 0x40—VOUT_OV_FAULT_LIMIT Bits Bit Name R/W Description [15:0] Mantissa Y R/W Unsigned Mantissa Y used in output voltage related commands in linear data format (V = Y × 2N). VOUT_OV_WARN_LIMIT The VOUT_OV_WARN_LIMIT command sets the overvoltage threshold (in volts) measured at the sense/output pin, VHx/VPx, that causes an overvoltage warning condition. Exponent N is set using VOUT_MODE[4:0]. Table 26. Register 0x42—VOUT_OV_WARN_LIMIT Bits Bit Name R/W Description [15:0] Mantissa Y R/W Unsigned Mantissa Y used in output voltage related commands in linear data format (V = Y × 2N). |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |