Motor de Búsqueda de Datasheet de Componentes Electrónicos
  Spanish  ▼
ALLDATASHEET.ES

X  

MLX90805S Datasheet(PDF) 6 Page - List of Unclassifed Manufacturers

No. de pieza MLX90805S
Descripción Electrónicos  Intelligent Triac Controller
PDF  13 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrónico  ETC [List of Unclassifed Manufacturers]
Página de inicio  
Logo ETC - List of Unclassifed Manufacturers

MLX90805S Datasheet(HTML) 6 Page - List of Unclassifed Manufacturers

Back Button MLX90805S Datasheet HTML 2Page - List of Unclassifed Manufacturers MLX90805S Datasheet HTML 3Page - List of Unclassifed Manufacturers MLX90805S Datasheet HTML 4Page - List of Unclassifed Manufacturers MLX90805S Datasheet HTML 5Page - List of Unclassifed Manufacturers MLX90805S Datasheet HTML 6Page - List of Unclassifed Manufacturers MLX90805S Datasheet HTML 7Page - List of Unclassifed Manufacturers MLX90805S Datasheet HTML 8Page - List of Unclassifed Manufacturers MLX90805S Datasheet HTML 9Page - List of Unclassifed Manufacturers MLX90805S Datasheet HTML 10Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 13 page
background image
MLX90805
Intelligent Triac Controller
MLX90805 Intelligent Triac Controller
Page 6
Rev 1.2
17/May/00
Pinout
Standard package is 8-pin dual inline package.
(Known as DIP-8, PDIP-8, DIL-8 and PDIL-8)
Precautions
Disturbance Immunity
According to pr EN 55014-2
ESD
All I/O pins must withstand the normalized ESD
pulses up to 2kV (100pF / 1.5 k
Ω). The pins will be
stressed in both polarities, with respect to the combi-
nation of all supply pins.
Pin
Name
Type
Description
1
SET
Input
Potentiometer input
2
THP
Input
Thermal protection
3
FB
Input
Feed back to create
hysteresis for thermal
protection
4
ZC
Input
Zero cross input
5
TRG
Output
Triac driver output
6
VSS
Supply
Ground
7
VDDA
Supply
Supply, high level
8
VREF
Output
Reference voltage
Options
The following options are available:
Firing angle definition
The firing angles, and corresponding motor speeds,
can be defined in ROMi[9:0]. This is the ROM table
which is addressed by the ADC reading the
potentiometer setting. The ROM contains 16 words
of 10 bits. For programming the different speed
settings in the ROM table, following formula can be
used, given ti (in msec) is the delay from the
previous zero crossing to the moment of ignition:
With: Fmains = frequency of the mains (in Hz)
Note:
The value should not be negative: very small values
can not be programmed.
The content of the ROM can be defined freely: it
does not need to be linear or continuous. However
for a proper softstart generation under all conditions,
the value with minimum firing angle (thus maximum
speed) must be in the highest ROM address.
Default values:
Rom address
Value
0
590
1
567
2
544
3
522
4
500
5
477
6
456
7
434
8
411
9
387
10
362
11
335
12
305
13
273
14
231
15
112
10
2
]
0
:
9
[
−
•
•
=
Fmains
ti
ROMi



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com