The main features of the M9203 are
➢ Complies with the User Interface Requirements of MIL-STD-1399-300B.
➢ Clean sine-wave input current – less than 3% harmonic current.
➢ Full-load Power Factor (PF) of above 0.98.
➢ Inrush current limiting.
➢ Conduction cooled via the baseplate.
➢ Inhibit Input, BIT and Current Monitor outputs.
➢ Overload, Overtemperature, Overvoltage and Missing-phase protections.
➢ Exceptional step-load response.
➢ Stable operation when loaded by large capacitance loads.
➢ Full galvanic isolation between Input, Chassis and Outputs.
➢ Withstands MIL-STD-1399-300B 2,500 V spikes.
➢ Complies with MIL-STD-461G for shipboard application.
➢ Complies with MIL-STD-167-1 (Type I) shipboard vibration.
➢ Robust mechanical design, intended for systems that should withstand MIL-DTL-901E high impact shocks.
➢ Up to 5 (five) identical M9203 unis can be connected in parallel (current share) and provide up to 16KW of regulated and protected power.
➢ Less than 1/5th of the Human Body Leakage limits of MIL-STD-1399-300B, allowing safe parallel connection of up to five M9203 units.
➢ J-STD-001B and IPC-610A Class-3 workmanship.
➢ Conformal Coating per MIL-I-46058C and IPC-CC-830.
|