  • FRTD-R-DA-L

  • AI
    The **FRTD-R-DA-L** is a specific model of a **Resistance Temperature Detector (RTD) Transmitter** (often associated with industrial automation brands like FineTek). It is designed to convert raw resistance signals from a PT100 sensor into a standardized linear output suitable for PLCs or controllers. --- ## 1. Technical Specifications Overview | Feature | Specification | | :--- | :--- | | **Input Type** | PT100 (Platinum Resistance) | | **Output Type** | 4-20mA (Analog Current Loop) | | **Configuration** | Head-mount / DIN Rail compatible (depending on housing) | | **Power Supply** | 12 ~ 35 VDC (Loop powered) | | **Accuracy** | ±0.1% F.S. | | **Temperature Range** | Configurable (e.g., -50°C to 200°C) | --- ## 2. Key Electronic Components The device consists of several critical internal stages that process the thermal data: ### A. The Input Bridge (Wheatstone Bridge) Since the PT100 sensor changes resistance based on temperature (100Ω at 0°C), the device uses a precision bridge circuit to detect these minute changes. * **Purpose:** Converts resistance variation into a small voltage signal. * **Compensation:** Often includes a 3-wire lead wire compensation to eliminate the resistance of the wires connecting the sensor to the transmitter. ### B. Signal Conditioning (Amplification) The raw voltage from the bridge is extremely small. An **Instrumental Operational Amplifier (Op-Amp)** is used to boost this signal while filtering out electromagnetic interference (EMI). ### C. Linearization Circuit RTD sensors are mostly linear, but not perfectly so. The internal electronics contain a linearization stage (analog or digital) to ensure the 4-20mA output is perfectly proportional to the temperature scale. ### D. V/I Converter (Voltage to Current) The final stage converts the processed voltage into a **4-20mA current loop**. * **4mA:** Represents the lowest temperature in the range. * **20mA:** Represents the highest temperature in the range. --- ## 3. Wiring and Terminal Layout Typical connection points for the FRTD-R-DA-L: | Terminal | Description | Function | | :--- | :--- | :--- | | **1 & 2** | Power/Signal Out | + and - Loop (DC 24V typical) | | **3, 4, 5** | Sensor Input | Connects to the PT100 (A, B, b wires) | --- ## 4. Part Number Breakdown (DA-L Logic) * **FRTD:** FineTek RTD Series. * **R:** Resistance input (PT100). * **DA:** Digital to Analog conversion / Standard Transmitter. * **L:** Refers to **Loop Powered** (meaning the device draws its operating power directly from the 4-20mA signal wires).
    ✨ Follow-up Questions
    • ⤷ How do I calibrate the zero and span on this transmitter?
    • ⤷ What is the difference between a 2-wire and 3-wire PT100 connection on this device?
    • ⤷ What are the common causes of a 22mA (overflow) output on the FRTD-R-DA-L?