4 / 28 page ![]() Digital Fiber Sensor FX-300 SERIES 142 Selection Guide Fibers Fiber Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS The use of only two switches makes for very simple operations All models Only two switches, the large jog switch and the large MODE key, are required for operation. You can operate it simply by the 3 steps shown on the right. Large MODE key Large jog switch Pressing the switch selects or cancels the operating mode Moving the switch from side to side allows items to be selected 2 3 Pressing the switch then confirms the selected setting 1 A quick-connection cable saves wiring and work-hours Connector type One unit can be used as either a main unit or sub unit The amplifier unit can be used as either a main unit or a sub unit. This feature allows for easy mounting in the side-by-side configuration. The main and sub unit functions are distinguished only by the proper use of the main cable and the sub cable. Moreover, inventory management and maintenance is simplified. An optical communication function allows up to *16 sensors to be adjusted simultaneously FX-301 FX-305 The optical communication function allows the data that is currently set to be copied and saved all at once for all amplifiers connected together from the right side. This greatly reduces troublesome setup tasks and makes setup much smoother. In addition, troublesome adjustment operations at times such as when replacing sensors can also be carried out easily and data can also be copied and stored using the optical communication function. Single copy & save operation for all amplifiers * Use the optical communication function for only the same types of sensors. Furthermore, the FX-301-HS is not equipped with optical communication function capability. Settings can be entered directly using numerical input All models Every function can be directly set merely by the input of a four digit code (numbers) from the code table. This convenient feature is easy to set up. In the event that settings are accidentally changed at the operating site, merely entering the correct code can restore the original settings. This results in easy and quick maintenance. First digit: Settings for response time and hysteresis Second digit: Settings for L/D ON and display mode Fourth digit: Timer period settings Third digit: Settings for Adjust lock and timer Identical part numbers eliminate the need for costly inventory management labor Sub cable Main cable Main cable (4-core) CN-74-C Sub cable (2-core) CN-72-C FX-305 Main cable (3-core) CN-73-C Sub cable (1-core) CN-71-C FX-301(-HS) FX-301B/G/H Upper communication unit for digital sensor SC-GU1-485 We now offer remote maintenance for digital sensors! The communication unit enables inputs to the digital fiber sensors (such as teaching and data bank switching) to be carried out via a PLC or a personal computer, and also allows confirming of the incident light intensity an output status for the fiber sensors. This greatly improves workability during equipment starting up and maintenance. Communication unit improves equipment starting up and maintenance FX-301 FX-305 External input unit for digital sensor FX-CH2 Teaching and changing settings can be performed by using the PLC and touch panel. Various settings and switching of up to 16 units of digital fiber sensors can be accomplished at once without operating the actual sensors themselves, but via external signals, such as the PLC, touch panel, and push buttons. Refer to our website for details • Batch teaching • Key lock setting • Batch loading / saving of the data bank <Main functions> RS-485 communication PLC Compatible with all PLCs equipped with RS-485 compatible units FX-301(P) FX-305(P) SC-GU1-485 • Sensor incident light intensity • Sensor settings verification • Sensor output status • Threshold value settings, etc. <Communicable commands> Refer to SC-GU1-485 pages for details |
Número de pieza similar - FD-61S |
|
Descripción similar - FD-61S |
|
|
Enlace URL |
| Política de Privacidad |
| ALLDATASHEET.ES |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |