| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
VBG-MOD-K20-D Datasheet(PDF) 2 Page - Pepperl+Fuchs Inc. |
|
|
|||||||||||||||||||||||||||||
VBG-MOD-K20-D Datasheet(HTML) 2 Page - Pepperl+Fuchs Inc. |
|
2 / 2 page ![]() VBG-MOD-K20-D AS-Interface gateway Germany: +49 621 776 4411 Pepperl+Fuchs Group Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. USA: +1 330 486 0001 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com 2 Function The VBG-MOD-K20-D is a MODBUS RTU gateway in accordance with AS-Interface- Specification 3.0 in IP20. The design makes it particularly suitable for use in control cabi- nets. The AS-Interface data can be used in many varied ways and for a variety of purposes. All the important data are available in both binary form as well as packed and unpacked via a register. So that the AS-Interface gateways can be operated with the MODBUS slave interface by the most varied of MODBUS masters, without having to resort to expensive adaptions. The gateway is supplied from the AS-Interface cable. The assignment of addresses and the accep- tance of the set configuration is possible by means of push button keys. 7 LEDs, arranged on the front of the device, indicate the current status of the AS-Interface network. On the AS-Interface Gateway, with graphic display, the commissioning of the AS-Inter- face circuit and the testing of the connected peripherals can be completely separated from the commissioning of the MODBUS and the programming. On-site operation using the graphics display and the 4 buttons enable all the functions to be depicted on the display that are covered by the other AS-Interface masters via the AS-i Control Tools software. An additional RS 232 socket provides the option of reading out data directly from the gateway, on gateway, network and function in the context of an extended on-site diagnosis. PLC Functionality Optionally, the gateway can be supplied with PLC functionality. Therefor you can order a code key VAZ-CTR additionally. Accessories VAZ-SW-ACT32 Full version of the AS-I Control Tools in- cluding connection cable USB-0,8M-PVC ABG-SUBD9 Interface converter USB/RS 232 Technical data General specifications AS-Interface specification V3.0 PLC-Functionality activateable Duplicate address detection from AS-Interface slaves Earth fault detection EFD integrated EMC monitoring integrated Diagnostics function Extended function via display UL File Number E223772 Functional safety related parameters MTTFd 90 a at 30 °C Indicators/operating means Display Illuminated graphical LC display for addressing and error mes- sages LED AS-i ACTIVE AS-Interface operation normal; LED green LED CONFIG ERR configuration error; LED red LED PRG ENABLE autom. programming; LED green LED POWER voltage ON; LED green LED PRJ MODE projecting mode active; LED yellow LED U AS-i AS-Interface voltage; LED green LED MODBUS MODBUS interface in operation, LED green Switch SET Selection and setting of a slave address OK button Mode selection traditional-graphical/confirmation Button MODE Mode selection PRJ-operation/save configuration/cursor ESC button Mode selection traditional-graphical/cancel Electrical specifications Insulation voltage Ui ≥ 500 V Rated operating voltage Ue from AS-Interface Rated operating current Ie ≤ 180 mA from AS-Interface Interface 1 Interface type RS-485 Protocol MODBUS RTU (Remote Terminal Unit) Interface 2 Interface type RS 232, serial Diagnostic Interface Transfer rate 19,2 kBit/s Connection AS-Interface spring terminals, removable MODBUS RS 485 interface Standard conformity Degree of protection EN 60529:2000 Ambient conditions Ambient temperature 0 ... 55 °C (32 ... 131 °F) Storage temperature -15 ... 75 °C (5 ... 167 °F) Mechanical specifications Degree of protection IP20 Mass 420 g Construction type Low profile housing , Stainless steel Notes In an AS-Interface network only one device can be operated earth fault detection. If there are many devices in an AS-Interface network, this can lead to the earth fault monitoring response threshold becoming less sensitive. |
Número de pieza similar - VBG-MOD-K20-D |
|
Descripción similar - VBG-MOD-K20-D |
|
|
|
Enlace URL |
| Política de Privacidad |
| ALLDATASHEET.ES |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |