| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
The question interval is too short.
Please try again in a few seconds.
Hello, Please ask a question about 301 Datasheet
# Example questions:
➢ How does the automatic temperature compensation feature benefit the performance of the echotel transducers described in the document?
➢ What are the primary application focuses or benefits highlighted for each model?
➢ What are some of the key features that the model 355 transmitter utilizes to improve accuracy and reliability in level measurement?
1. Overview - What These Devices Are:
️· Type: Ultrasonic Level/Interface Transmitters (specifically, models 335, 344/345, and 355). These devices use ultrasonic waves to measure the level of liquids or interfaces (boundaries between liquids) in tanks and vessels.
️· Application: Primarily designed for industrial applications, including chemical processing, water/wastewater, food & beverage, and power generation.
️· Key Benefit: Non-contact measurement - no need to submerge a sensor in the process liquid, reducing maintenance and eliminating potential contamination.
2. Model-Specific Features and Specifications (See below for a table summarizing this)
3. General Features Across Models:
️· Temperature Compensation: Automatic temperature compensation to ensure accurate measurements despite temperature fluctuations.
️· Multiple Output Options: Options include 4-20mA isolated output and HART communication (model 355).
️· Fail-Safe Options: Programmable fail-safe features (holding last known value or going to a defined output) in case of sensor failure.
️· Easy Configuration: Many models offer front-panel keypads and alphanumeric displays for easy setup and parameter adjustment.
️· Echo Rejection: Techniques to filter out unwanted echoes (like from tank obstructions).
- Model 355 has a patent-pending "Temperature Compensated Echo Rejection" which constantly adjusts based on temperature.
️· Enclosure Options: Available in various materials like cast aluminum and Lexan for different environmental conditions.
4. Table of Model-Specific Information:
| Feature | Model 335 | Model 344/345 | Model 355 |
|---|---|---|---|
| Frequency | 60 kHz | 38 kHz (344) / 50 kHz (345) | 60 kHz |
| Output | 4-20mA | 4-20mA, RS-232 | 4-20mA (HART) |
| Power Supply | 16-36 VDC | 120/240 VAC, 24 VDC | 16-36 VDC |
| Echo Rejection | Standard | Standard | Temperature Compensated |
| Display | LCD | Alphanumeric LCD | 2-line x 16 character LCD |
| Max. Range | 20 feet (6 meters) | N/A | Not specified in document |
| Key Features | Automatic self-test, selectable damping | Dual flow totalizers, stored tank shapes | HART communication, temperature compensation |
1. Overview - What These Devices Are:
️· Type: Ultrasonic Level/Interface Transmitters (specifically, models 335, 344/345, and 355). These devices use ultrasonic waves to measure the level of liquids or interfaces (boundaries between liquids) in tanks and vessels.
️· Application: Primarily designed for industrial applications, including chemical processing, water/wastewater, food & beverage, and power generation.
️· Key Benefit: Non-contact measurement - no need to submerge a sensor in the process liquid, reducing maintenance and eliminating potential contamination.
2. Model-Specific Features and Specifications (See below for a table summarizing this)
3. General Features Across Models:
️· Temperature Compensation: Automatic temperature compensation to ensure accurate measurements despite temperature fluctuations.
️· Multiple Output Options: Options include 4-20mA isolated output and HART communication (model 355).
️· Fail-Safe Options: Programmable fail-safe features (holding last known value or going to a defined output) in case of sensor failure.
️· Easy Configuration: Many models offer front-panel keypads and alphanumeric displays for easy setup and parameter adjustment.
️· Echo Rejection: Techniques to filter out unwanted echoes (like from tank obstructions).
- Model 355 has a patent-pending "Temperature Compensated Echo Rejection" which constantly adjusts based on temperature.
️· Enclosure Options: Available in various materials like cast aluminum and Lexan for different environmental conditions.
4. Table of Model-Specific Information:
| Feature | Model 335 | Model 344/345 | Model 355 |
|---|---|---|---|
| Frequency | 60 kHz | 38 kHz (344) / 50 kHz (345) | 60 kHz |
| Output | 4-20mA | 4-20mA, RS-232 | 4-20mA (HART) |
| Power Supply | 16-36 VDC | 120/240 VAC, 24 VDC | 16-36 VDC |
| Echo Rejection | Standard | Standard | Temperature Compensated |
| Display | LCD | Alphanumeric LCD | 2-line x 16 character LCD |
| Max. Range | 20 feet (6 meters) | N/A | Not specified in document |
| Key Features | Automatic self-test, selectable damping | Dual flow totalizers, stored tank shapes | HART communication, temperature compensation |
| Part No. | 301 |
| Manufacturer | MAGNETROL |
| Size | 768 Kbytes |
| Pages | 8 pages |
| Description | ECHOTEL짰NON-CONTACTULTRASOUND |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |